CORC

浏览/检索结果: 共21条,第1-10条 帮助

限定条件                
已选(0)清除 条数/页:   排序方式:
High-Precision and Short-Time Solar Forecasting by Spaceborne Solar Irradiance Spectrometer 期刊论文
Guangxue Xuebao/Acta Optica Sinica, 2019, 卷号: 39, 期号: 7
作者:  Z.Li;  S.Wang;  Y.Huang;  G.Lin;  Y.Shao
收藏  |  浏览/下载:0/0  |  提交时间:2020/08/24
Target geo-location based on laser range finder for airborne electro-optical imaging systems 期刊论文
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 卷号: 27, 期号: 1, 页码: 8-16
作者:  H.Zhang;  C.Qiao;  H.-P.Kuang
收藏  |  浏览/下载:0/0  |  提交时间:2020/08/24
Error-compensation of angular displacement measurement based on posteriori error fitting 期刊论文
Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 卷号: 27, 期号: 1, 页码: 51-57
作者:  H.Yu;  Q.-H.Wan;  C.-H.Zhao;  X.-R.Lu;  Y.-C.Du
收藏  |  浏览/下载:1/0  |  提交时间:2020/08/24
Correction Algorithm of Systemic Errors in Grating Lateral-Shearing Interferometer 期刊论文
Zhongguo Jiguang/Chinese Journal of Lasers, 2018, 卷号: 45, 期号: 8
作者:  Zhang, Lu;  Xiang, Yang
收藏  |  浏览/下载:5/0  |  提交时间:2019/09/17
Wide Field of View Turbulence Profile Measurement Method 期刊论文
Zhongguo Jiguang/Chinese Journal of Lasers, 2018, 卷号: 45, 期号: 8
作者:  Fang, Yuliang;  Jin, Zhenyu;  Liu, Zhong;  Li, Zhenggang
收藏  |  浏览/下载:5/0  |  提交时间:2019/09/17
Metrology and calibration of GSSMP rotation accuracy 期刊论文
Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2018, 卷号: 47, 期号: 9
作者:  An, Qichang;  Zhang, Jingxu;  Yang, Fei;  Zhao, Hongchao
收藏  |  浏览/下载:4/0  |  提交时间:2019/09/17
Precision analysis of simulation systems with hardware-in-loop caused by performance of three-Axis virtual flight motion simulator (EI CONFERENCE) 会议论文
2011 International Conference on Manufacturing Science and Technology, ICMST 2011, September 16, 2011 - September 18, 2011, Singapore, Singapore
Wang T.; Zhu M.-C.; Yin S.-L.; Jia H.-G.
收藏  |  浏览/下载:32/0  |  提交时间:2013/03/25
Simulation systems with hardware-in-loop are composed by three-Axis virtual flight motion simulator  simulation computer  load torque simulator  and visual simulation systems. Three-Axis Virtual Flight Motion Simulator are used to simulate the attitude of missile in simulation system with hardware-in-loop  so its performance influenced the result of simulation directly. This paper mainly analyzed the factors which influenced the performance of a three-Axis virtual flight motion simulator which we are used now in the lab  then analyzed the entire simulation system's error caused by these factors through numerical simulation method. By analysis we can see that bandwidth is the main factor influenced the precision of simulation systems with hardware-in-loop  mechanical device installation error and measurement error may also cause some errors of the systems at the same time.  
Simulation test research of using the Ritchey-Common method for the detection of large flat mirror (EI CONFERENCE) 会议论文
2012 International Conference on Frontiers of Advanced Materials and Engineering Technology, FAMET 2012, January 4, 2012 - January 5, 2012, Xiamen, China
Zhu S.; Zhang X.
收藏  |  浏览/下载:11/0  |  提交时间:2013/03/25
The research on adaptive measurement of angular acceleration for photoelectric servo turntable (EI CONFERENCE) 会议论文
2011 International Conference on Mechatronic Science, Electric Engineering and Computer, MEC 2011, August 19, 2011 - August 22, 2011, Jilin, China
Liang W.; Guo J.; Chen J.; Feng F.
收藏  |  浏览/下载:15/0  |  提交时间:2013/03/25
The paper proposes a new measurement method of angular acceleration for photoelectric servo turntable. Piezoelectric angular acceleration sensor is used to measure angular acceleration directly  Adaptive FIR filter based on LMS algorithm is established on DSP  by which angular acceleration signal can be filtered and corrected errors adaptively  then angular acceleration signals can be measured adaptively. This method avoids measurement errors and calculation noise by computing angular acceleration indirectly  thus improving measurement precision and making measurement results better than traditional methods. The gotten angular acceleration can be sent to servo control mechanism as feed forward control signals to improve control effects of servo turntable significantly. 2011 IEEE.  
Performance test of steel tube enclosed thermistors in air temperature measurements (EI CONFERENCE) 会议论文
3rd International Conference on Measuring Technology and Mechatronics Automation, ICMTMA 2011, January 6, 2011 - January 7, 2011, Shanghai, China
Chen H.; Peng J.; Yan F.; Sui Y.; Yang H.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
The performances of two steel tube enclosed precision thermistors are tested in a well controlled air environment to determine if the thermistors have enough accuracy for 0.01C levels of air temperature gradient measurement. Three Fluke's 5641 and three 5610 thermistors were tested for 24 hours in Fluke's 7008 calibration bath in the first step. In the second step  the performances of these two thermistors in steady state and transient state air temperature environments were tested for 8 hours separately. The results illustrate that  two of the 5641s were airproofed in a temperature well controlled tube  when steel tube enclosed precision thermistors are used in air temperature measurement  there are unstable departures from each other with a maximum 8.8 mC in constant air medium and 27 mC in temperature changing air medium. The transient-time errors are too large to show the true amounts of temperature changes for air temperature measurement. 2011 IEEE.  


©版权所有 ©2017 CSpace - Powered by CSpace