Structure and magnetic properties of (Al, Co) Co-doped ZnO thin films (EI CONFERENCE)
会议论文
2012 International Conference on Materials Science and Nanotechnology, ICMSN 2012, November 16, 2012 - November 18, 2012, Guangzhou, China
Cao P.
;
Bai Y.
收藏
  |  
浏览/下载:23/0
  |  
提交时间:2013/03/25
In this study
Zn0.99Co0.01Al0.015O thin film has been prepared by sol-gel method. The structural and magnetic properties of the sample were investigated. X-ray diffraction spectroscopy analyses indicate that the Co and Al codoping can not disturb the structure of ZnO. No additional peaks are observed in the Zn0.99Co0.01Al xO and Al3+ and Co2+ substitute for Zn 2+ without changing the wurtzite structure. The resistance measurements confirm that Al ions increase the free carriers concentration. Based on the above experiments we think the ferromagnetic behavior of the sample could not originate from Co nanoclusters. The presence of free carriers and localized d spins is a prerequisite for the appearance of ferromagnetism. As the result
the carriers generated by Al doping is considered a main factor to induce the ferromagnetic phenomenon. (2013) Trans Tech Publications
Switzerland.
Laser cleaning of neutral attenuator plate based on low power laser diode (EI CONFERENCE)
会议论文
2nd International Conference on Energy, Environment and Sustainable Development, EESD 2012, October 12, 2012 - October 14, 2012, Jilin, China
Gan X.
;
Chen Y.
;
Li L.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
Laser cleaning is a non-contact
green and environmental cleaning method
which can effectively remove particulate contaminations of sizes as small as 0.1 m without damage to the optics. But most laser cleaning devices are large and heavy
also expensive due to using large lasers such as CO2 laser
YAG Laser etc. In this work a low power LD was tried to clean fingerprint and dust contaminated on the surface of the attenuator glasses plates. In the laser cleaning experiment with low power diode the fingerprint grease can be efficient to be cleaned
but there is no evident effect for cleaning inorganic dust. The cleaning different degree of fingerprint contaminations was investigated at the variable laser parameters
including laser power and irradiation time. An optical microscope was used to analyze the cleaning effect. The results show that low power LD can effectively remove the fingerprint on the surface of absorptive-type attenuator glass plates. On the premise that the attenuator optics glasses are not damaged
the cleaning area increases with the increase of radiation time and laser power. The cleaning area doesn't change much with the variation of laser frequency when the other parameters are the same. (2013) Trans Tech Publications
Switzerland.
Immersed nanospheres super-lithography for the fabrication of sub-70nm nanoholes with period below 700nm (EI CONFERENCE)
会议论文
2012 12th IEEE International Conference on Nanotechnology, NANO 2012, August 20, 2012 - August 23, 2012, Birmingham, United kingdom
Li S.
;
Shi L.
;
Yang Z.
;
Huang X.
;
Zhang Z.
;
Gao F.
;
Guo Y.
;
Yu W.
;
Du J.
收藏
  |  
浏览/下载:129/0
  |  
提交时间:2013/03/25
A maskless nano-lithography method by using polystyrene spheres (PSs) self-assembled on silver slab (NSSL) was proposed in [optics express
Vol. 16
No. 19 (2008) 14397]. Following that
to break the limitations in resolution and PSs period of NSSL method
in this paper
we present PSs immersed super-resolution lithography (NSISL) technology by embedding the PSs into appropriate material to improve the efficiency of the surface plasmon excitation. The energy modulating mechanism and the rules of the resolution affected by silver slab were studied by calculating and analysing the energy distribution. The curve of the lithography resolution versus the silver thickness was presented. In order to verify this method
contrast analysis was carried out with NSSL. The results show that the lithography resolution is improved efficiently. Taking a specific configuration with PS diameter of 600nm as an example
the resolution was improved to 54nm from 190nm with Ag thickness of 25nm. Based on the calculation results
we carried out the experiments. Nano holes with dimension of 75nm and period of 600nm were obtained. 2012 IEEE.
High beam quality all-solid-state 1053nm nd: Glass amplifier shaping by LCSLM at repetition frequency (EI CONFERENCE)
会议论文
2nd International Conference on Optical, Electronic Materials and Applications 2012, OEMA 2012, May 25, 2012 - May 26, 2012, Chongqing, China
Qiu J.
;
Fan Z.
;
Tang X.
;
Lian F.
;
Zhang X.
;
Ma Y.
收藏
  |  
浏览/下载:73/0
  |  
提交时间:2013/03/25
A laser amplifier of LD pumping Nd: glass with a high beam quality and stability
the modulation degree near field is less than 1.23:1. (2012) Trans Tech Publications
which amplifies nanosecond laser pulse
Switzerland.
has been developed in this paper. Under 1Hz repetition frequency
when the flat top pulse of 3 ns width and 1 nJ energy is injected as the seed pulse
the average output energy of the laser amplifier is 115.3 mJ with a net gain of 109
the energy dispersion degree of the outputting laser is no more than 2%
Improved TOPS about direction of arrival estimation for wideband signals (EI CONFERENCE)
会议论文
2011 International Conference on Vibration, Structural Engineering and Measurement, ICVSEM2011, October 21, 2011 - October 23, 2011, Shanghai, China
He B.
收藏
  |  
浏览/下载:13/0
  |  
提交时间:2013/03/25
The study about the direction-of-arrival (DOA) estimation for wideband signals is a basic topic of Signal Processing. The method called test of orthogonality of projected subspaces (TOPS) does not require initial values to form focusing matrix compared with the coherent signal subspace method (CSSM)
but it has poor performance for coherent wideband signals at low signal-to-noise ratio (SNR). Based on the lack of the conventional TOPS
this paper reconstructs a set of new matrices with the narrowband correlated matrices coming from the DFT decomposition of the array output and modifies the method frame of the conventional TOPS. So we get a set of reconstructed matrices with full rank corresponding to each frequency bin
and which have no array aperture loss. The improved TOPS can estimate the DOA for coherent wideband sources at low SNR
and enhances the performance of the conventional TOPS. Simulation results show that the improved TOPS is effective
and the total performance of which is similar to the rotational signal-subspace (RSS) method. (2012) Trans Tech Publications.
Reagentless near-infrared determination of cholesterol in undiluted human serum using interval partial least square (EI CONFERENCE)
会议论文
2011 International Conference on Smart Materials and Nanotechnology in Engineering, SMNE 2011, September 17, 2011 - September 18, 2011, Wuhan, China
Gao H.
;
Lu Q.
;
Huang F.
收藏
  |  
浏览/下载:21/0
  |  
提交时间:2013/03/25
In order to determination of cholesterol in human serum with no reagent using nearinfrared (NIR) spectroscopy. Interval partial least square (iPLS) was proposed as an effective variable selection approach for multivariate calibration. For this purpose
an independent sample set was employed to evaluate the prediction ability of the resulting model. The spectrum was split into different interval. Then
the informative region of cholesterol (1688-1760nm)
in which the PLS model has a low RMSEP with 0.241mmol/L and a high R with 0.975
is selected with 23 intervals. The results indicate that
the informative region of cholesterol can be obtained by iPLS and applied to design the simpler reagentless NIR instruments for inexpensive cholesterol measurement in future. (2012) Trans Tech Publications
Switzerland.
Application of trend extrapolation method to spectrum analysis of microtremor signal (EI CONFERENCE)
会议论文
2nd World Congress on Computer Science and Information Engineering, CSIE 2011, June 17, 2011 - June 19, 2011, Changchun, China
Zhou X.
;
Guo T.
;
Jiao J.
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2013/03/25
The trend extrapolation method is applied to spectrum analysis of microtremor signal in order to increase the spectral estimation accuracy. First
establish an appropriate extrapolation model based on the existing data series
and then fit correlation functions other than existing data by derivative least squares method
finally perform spectrum analysis using extrapolated correlation functions. Numerical simulations and the experimental results show that good results are achieved no matter correlation functions change slow or rapid
and the extrapolation error is not more than 2.3%. 2012 Springer-Verlag Berlin Heidelberg.
Control of N/N2 species ratio in NO plasma for p-type doping of ZnO (EI CONFERENCE)
会议论文
Chen X.
;
Zhang Z.
;
Yao B.
;
Jiang M.
;
Wang S.
;
Li B.
;
Shan C.
;
Liu L.
;
Zhao D.
;
Shen D.
收藏
  |  
浏览/下载:15/0
  |  
提交时间:2013/03/25
Nitrogen-doped ZnO thin films were grown on c-plane sapphire (Al 2O3) substrates via plasma-assisted molecular beam epitaxy using plasma activated nitric oxide (NO) as the oxygen source and dopant. X-ray diffraction measurements indicate that a small NO flux benefits the crystal quality of the thin films. Hall effect measurements indicate that the electron density of the ZnO films decreases gradually with decreasing NO flux
and the conduction reverses to p-type at a certain flux. Optical emission spectra indicate that the N atom content in the NO plasma increases with decreasing NO flux
and the origin of this is discussed. X-ray photoelectron spectroscopy measurements demonstrate that the number of N atom occupied O sites in the ZnO lattice increases correspondingly. 2011 American Institute of Physics.
An appraisal method of dynamic interpolation error for high precision encoder (EI CONFERENCE)
会议论文
2011 International Conference on Electronics and Optoelectronics, ICEOE 2011, July 29, 2011 - July 31, 2011, Dalian, China
Yi J.
;
An L.-M.
;
Liu C.-X.
;
Wan Q.-H.
收藏
  |  
浏览/下载:10/0
  |  
提交时间:2013/03/25
This paper introduces an appraisal method of the dynamic interpolation error for the high precision encoder (Lissajou pattern calculation method). When the encoder is rolling
two groups of fine photoelectric signals whose phase difference are /2 can be collected using data collected car. The shape and position deviation can be obtained through the comparison between Lissajou charts and the standard circle. Then dynamic interpolation error can be calculated out directly. This method is immune to the influence of encoder's speed and has no rigid demand to the test circumstances and test devices. The experimental results indicate that this method is feasible and important to the encoder's dynamic interpolation error checking. 2011 IEEE.
Scanning program of image guided missile basing on parabolic trajectory (EI CONFERENCE)
会议论文
3rd IEEE International Conference on Advanced Computer Control, ICACC 2011, January 18, 2011 - January 20, 2011, Harbin, China
Wang Y.
收藏
  |  
浏览/下载:12/0
  |  
提交时间:2013/03/25
In order to have a larger scanning area of image guided missile which fight baseing on parabolic trajectory
improve the probability of capture by the seeker
a program is presented in the paper. The program not only can meet the requirement of the capture probability
but also can scan the whole area of target maneuvering
and there is no blind area in the scanning area. 2011 IEEE.
©版权所有 ©2017 CSpace - Powered by