CORC

浏览/检索结果: 共8条,第1-8条 帮助

限定条件    
已选(0)清除 条数/页:   排序方式:
Commissioning of the China-ADS Injector-I Testing Facility 会议论文
Proceedings of the 7th International Particle Accelerator Conference, Korea, 2016
作者:  F.Yan;  J.S.Cao;  Y.L.Chi;  R.Ge;  H.Geng
收藏  |  浏览/下载:69/0  |  提交时间:2016/07/13
Protective effects of ischemic preconditioning on myocardial ischemia reperfusion injury 会议论文
作者:  Xia, Cao (1);  Kewei, Ma (3);  Bing, Han (1);  Xiaofeng, Yu (1);  Shaochun, Qu (1)
收藏  |  浏览/下载:2/0  |  提交时间:2019/12/05
Effects of Ginsenoside Re on myocardial ischemia reperfusion injury 会议论文
作者:  Cao Xia (1);  Ma Kewei (4);  Liu Yicheng (1);  Yu Xiaofeng (1);  Chen Yanping (3)
收藏  |  浏览/下载:4/0  |  提交时间:2019/12/05
Temperature gradients effect on surface test with high precise interferometer 会议论文
2010
Miao E. L.; Gu Y. Q.; Zhang J. A.; Sui Y. X.; Yang H. J.
收藏  |  浏览/下载:24/0  |  提交时间:2013/03/28
Target characteristic extraction algorithm based on block structure variables (EI CONFERENCE) 会议论文
2010 3rd International Conference on Advanced Computer Theory and Engineering, ICACTE 2010, August 20, 2010 - August 22, 2010, Chengdu, China
Zhou Y.; Gu Y.; Yan F.; Sui Y.; Yang H.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25
Temperature gradients effect on surface test with high precise interferometer (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Miao E.-L.; Gu Y.-Q.; Zhang J.; Sui Y.-X.; Yang H.-J.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
In high precise surface testing  temperature stability and uniformity are of paramount importance to the high accuracy of test results. Micro-temperature variation and temperature gradients not only cause the change of the air refractive index and lead to the optical path variation in interferometer cavity  but also result in deformation of the tested surface itself  which always brings about errors to the test results. Temperature effects on the interferometer cavity and the tested surface are analyzed from the axial and radial directions in this letter. Temperature model of the interferometer cavity and the tested lens are established and quantitative calculations and diagram of test results versus temperature and lens dimension are provided. It shows that temperature gradients effect increase with the length of the interferometer and the dimension of the tested lens. The interferometer cavity is mainly affected by radial temperature gradients while the tested lens is mainly affected by the axial temperature gradients. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Simulation of a monolithically integrated CMOS bioamplifier for EEG recordings 会议论文
ieee conference on electron devices and solid-state circuits, kowloon, peoples r china, dec 19-21, 2005
Sui XH (Sui Xiaohong); Liu JB (Liu Jinbin); Gu M (Gu Ming); Pei WH (Pei Weihua); Chen HD (Chen Hongda)
收藏  |  浏览/下载:210/71  |  提交时间:2010/03/29
Circuit design and simulation of a CMOS-based preamplifier for brain neural signals 会议论文
1st international conference on neural interface and control (cnic), wuhan, peoples r china, may 26-28, 2005
Sui XH; Pei WH; Gu M; Liu JB; Chen HD
收藏  |  浏览/下载:132/33  |  提交时间:2010/03/29
BCI  


©版权所有 ©2017 CSpace - Powered by CSpace