CORC

浏览/检索结果: 共10条,第1-10条 帮助

限定条件                    
已选(0)清除 条数/页:   排序方式:
Feed-forward control to stabilize optical axis based on accelerometer (EI CONFERENCE) 会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Wenfeng B.; Juan C.; Hu W.
收藏  |  浏览/下载:15/0  |  提交时间:2013/03/25
Timing generator of scientific grade CCD camera and its implementation based on FPGA technology (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optoelectronic Materials and Devices for Detector, Imager, Display, and Energy Conversion Technology, April 26, 2010 - April 29, 2010, Dalian, China
Si G.; Li Y.; Guo Y.
收藏  |  浏览/下载:21/0  |  提交时间:2013/03/25
The Timing Generator's functions of Scientific Grade CCD Camera is briefly presented: it generates various kinds of impulse sequence for the TDI-CCD  video processor and imaging data output  acting as the synchronous coordinator for time in the CCD imaging unit. The IL-E2TDI-CCD sensor produced by DALSA Co.Ltd. use in the Scientific Grade CCD Camera. Driving schedules of IL-E2 TDI-CCD sensor has been examined in detail  the timing generator has been designed for Scientific Grade CCD Camera. FPGA is chosen as the hardware design platform  schedule generator is described with VHDL. The designed generator has been successfully fulfilled function simulation with EDA software and fitted into XC2VP20-FF1152 (a kind of FPGA products made by XILINX). The experiments indicate that the new method improves the integrated level of the system. The Scientific Grade CCD camera system's high reliability  stability and low power supply are achieved. At the same time  the period of design and experiment is sharply shorted. 2010 Copyright SPIE - The International Society for Optical Engineering.  
3R intersection target positioning in real time based on distance (EI CONFERENCE) 会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Nengwei W.; Juan C.; Jian C.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
The positioning error based on angle  angle-distance or single station positioning increases with the distance increasing. 3R target positioning based on distance can obtain the high precision measurements in long distance. Here we give the 3R model for the intersection positioning  provide the two necessary conditions for getting the optimum intersection point. The experimental results show that the intersection precision based on angle is over 2m and will degrade greatly with the increasing of distance while the one based on 3R model will improve and the error decrease gradually. That the precision of the distance measurement is about 1m means the 3R model is better than the angle positioning  which can compensate the drawbacks of the angle positioning at short distance. 2010 IEEE.  
Research on radiometric calibration of interline transfer CCD camera based on TDI working mode (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Wu X.-X.; Liu J.-G.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
Interline transfer CCD camera can be designed to work in time delay and integration mode similar to TDI CCD to obtain higher responsivity and spatial resolution under poor illumination condition. However it was found that outputs of some pixels were much lower than others' as interline transfer CCD camera work in TDI mode in laboratory radiometric calibration experiments. As a result photo response non-uniformity(PRNU) and signal noise ratio(SNR) of the system turned for the worse. This phenomenon's mechanism was analyzed and improved PRNU and SNR algorithms of interline transfer CCD camera were advanced to solve this problem. In this way TDI stage was used as a variant in PRNU and SNR algorithms and system performance was improved observably with few influences on use. In validation experiments the improved algorithms was applied in radiometric calibration of a camera with KAI-0340s as detector. Results of validation experiments proved that the improved algorithms could effectively improve SNR and lower PRNU of the system. At the same time characteristic of the system could be reflected better. As working in 16 TDI stages  PRUN was reduced from 2.25% to 0.82% and SNR was improved about 2%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
High accuracy star image locating and imaging calibration for star sensor technology (EI CONFERENCE) 会议论文
6th International Symposium on Precision Engineering Measurements and Instrumentation, August 8, 2010 - August 11, 2010, Hangzhou, China
Zhang S.; Zhang Z.; Sun H.; Wang Y.
收藏  |  浏览/下载:12/0  |  提交时间:2013/03/25
Today aircraft attitude measurement technology plays an important role in an aircraft system because it can provide orientation for aircraft in action. Lately star sensor technology used in aircraft attitude measurement has become more and more popular because of its high accuracy  light weight  without attitude accumulation errors and other advantages. There are three main steps for star sensor to measure aircraft attitude  star image locating  star identification and attitude tracking. The latter two steps are based on the accuracy of star image locating. So it's critical to make efforts to advance the accuracy of star image locating. Some imaging errors  such as spherical aberration or coma aberration  also have negative effect on the accuracy of star image locating  of which the effect is necessarily reduced as well. At the beginning of this article  the structure of star sensor hardware is introduced. Secondly three methods for star image locating are described specifically  which are traditional centroid method  Gauss quadric fitting method and improved Gauss quadric fitting method. Subsequently an imaging calibration method is described for the purpose of reducing the effect of imaging errors. Finally the experiment shows that the accuracy of the star sensor is 2-arc-second. 2010 SPIE.  
The design of missile's dome that fits both optical and aerodynamic needs (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Smart Structures and Materials in Manufacturing and Testing, April 26, 2010 - April 29, 2010, Dalian, China
Wei Q.; Zhang X.; Jia H.
收藏  |  浏览/下载:10/0  |  提交时间:2013/03/25
A real-time two-dimensional correlation speed measurement based on image (EI CONFERENCE) 会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Zhang Y.-X.; Xu Z.-P.; Yu L.; Ge W.-Q.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
In order to implement two-dimensional moving object's non-contact and real-time speed measurement  in this paper  wc proposed a new method which was based on the characteristic of FPGA and a real-time two-dimensional correlation speed measurement was proposed on image processing using high speed CMOS shown in figure 1. Experimental installation was shown in figure 2  a cardboard with images which was fixed in electric control movement device was moving to simulate moving object  the CMOS image sensor gathered image signals of the cardboard and the image signals was output to FPGA after a serials pretreatment such as binaryzation etc. Logical operation insteaded mathematical operation on FPGA to implement two frames image's cross-correlation operations as the formula (10) in this paper  and finally calculate the two-dimensional velocity. Through experiment result of table 1 we drawn an conclusion the accurarcy of the method in this paper was less than 1 pixel and the method can be used at a certain speed ranges of two-dimensional  real-time speed measurement. 2010 IEEE.  
Linearity measurement for image-intensified CCD (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Zhao Y.; Zhang L.; Yan F.; Gu Y.; Wan L.
收藏  |  浏览/下载:22/0  |  提交时间:2013/03/25
To the characteristic of the ultraviolet CCD (UV ICCD)  technique of the linearity measurement of the UV ICCD camera is studied based on the theory of radiometry. Approach of linearity measurement is discussed  and a kind of measurement system of the UV ICCD has been developed based on the method of neutral density filter. It is very important that the transmittance of the filter is independent of the wavelength in the method of neutral density filter. Black metal screen mesh with different transmittance is used in our system  and calibration of the filters' transmittance in different working positions has been done. Meanwhile  to assure the uniform of the received radiation on the target of the detector at any test points  an integrating sphere is placed behind the neutral filter to balance light. The whole measurement system mainly consists of a deuterium lamp with high stabilization  the attenuation film with transmission  integrating sphere  optical guide and electro-shift platform. Auto control is realized via special software during the test. With this instrument  the linearity of the UV ICCD was measured. Experimental results show that the nonlinearity of the UV ICCD under fixed-gain is less than 2% and the uncertainty of measurement system is less than 4%. 2010 Copyright SPIE - The International Society for Optical Engineering.  
New phase measurement method for laser rangefinder (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Sun W.-J.; Sun J.-N.; Bu W.-B.; Meng Z.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
A new phase measurement method is designed and presented by using the technique of signal shifting phase and the technique of signal multiplication for laser rangefinder. The intensity of laser light is modulated by cosine circuit signal  at the same time the cosine circuit signal is thansformed sine signal by the shifting phase technique. Two signals mentioned above are multiplied by received signal from the target respectively  then being transmitted into signal processor after passing through low band filter respectively. The result of phase-shift between the received signal and sent signal is calculated by means of signal processor and time-counter with double frequency of modulation signal. The proposed system is composed of four units such as control and count unit  emitting and receiving unit of laser light  signal processing unit and result display unit. The two most advantages of proposed system over others are its ability of proper isolation which reduces crosstalk and its independency thermal drift. Theoretical calculations and experimental results have shown the accuracy better than 2 mm. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Structural and photoluminescence properties of aligned Sb-doped ZnO nanocolumns synthesized by the hydrothermal method (EI CONFERENCE) 会议论文
Fang X.; Li J.; Zhao D.; Li B.; Zhang Z.; Shen D.; Wang X.; Wei Z.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25


©版权所有 ©2017 CSpace - Powered by CSpace