CORC

浏览/检索结果: 共4条,第1-4条 帮助

限定条件    
已选(0)清除 条数/页:   排序方式:
The angular velocity estimation principal of -- filter based on high sampling rate (EI CONFERENCE) 会议论文
2011 2nd International Conference on Mechanic Automation and Control Engineering, MACE 2011, July 15, 2011 - July 17, 2011, Inner Mongolia, China
Zhang Y.; Chu H.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
In order to get angular velocity of stabilization servo mechanism from angular position sensors  -- filter and its angular velocity transfer function were predigested. Combing with optimum parameters  -- filter based on high sampling rate was established  the effect of and sample rate on filter nature frequency were evaluated. According to the requirements of stabilization platform  the principle of steady and transient tracking filter differential were proved. With the hypothesis of constant acceleration  the frequency characteristics of angular velocity transfer function were analyzed  three-dimensional Kalman filter was simplified  and the filter parameters were designed. The results show that when the spectrum of input signal was lower than 6rad/s  parameters was 0.02  and sampling period were 0.08ms and 0.1ms respectively  the filter can realize differential exactly  when the spectrum was 9rad/s  the precision was no less than 1.1%  the phase leading of angular position was no less than 70  the natural frequency should be higher than the cut-off frequency of stabilization platform was two or three times. In the engineering of electro-optical stabilization servo mechanism  -- filter has properties of tracking differential  and reached the requirement of platform angular velocity estimation. Also it is one of the effective methods to get angular velocity from angular position sensors. 2011 IEEE.  
A new method of image reconstruction with high resolution in X-ray coded aperture imaging (EI CONFERENCE) 会议论文
Laser-Generated, Synchrotron, and Other Laboratory X-Ray and EUV Sources, Optics, and Applications II, August 2, 2005 - August 4, 2005, San Diego, CA, United states
Hu J.; Cheng L.; Wu X.; Sun Y.; Bai Y.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
In the processing diagnosis of the inertia confinement fusion (ICF)  the ring coded aperture imaging technique is applied in order to gain high space and time resolutions simultaneously. The key of acquiring high spatial resolution is how to obtain a point spread function of an imaging system. The common method is the firsthand projection method which is an approximate one. The x-ray diffraction effect is neglected in the method  so the resolution of reconstructed image is decreased. We have derived the point spread function (PSF) of the ring coded aperture from scalar diffraction theory. And the Wiener filter is fabricated on the basis of the PSF. In National Key Laboratory of Laser Fusion  at China Academy of Engineering Physics  the imaging experiment on the diagnosis of ICF is completed using the ring coded aperture plate with inner diameter d1 = 250m and outer diameter d2 = 260m . The obtained coded image is processed by the Wiener filter which diffractive effect is considered. The processed results have shown that resolution and modulation contrast of acquired image are evidently better than the results obtained by the firsthand projection method.  
Optically-active nanocrystals for inner filter effect-based fluorescence sensing: Achieving better spectral overlap 会议论文
TrAC Trends in Analytical Chemistry, 183-190, 2019
作者:  Jinyi Zhang;  Ronghui Zhou;  Dandan Tang;  Xiandeng Hou;  Peng Wu
收藏  |  浏览/下载:1/0  |  提交时间:2019/12/13
Fluorescent TiC MXene quantum dots for an alkaline phosphatase assay and embryonic stem cell identification based on the inner filter effect 会议论文
Nanoscale, 19579-19585, 2018
作者:  Zheng Guo;  Xiaohua Zhu;  Shigong Wang;  Chunyang Lei;  Yan Huang
收藏  |  浏览/下载:2/0  |  提交时间:2019/12/25


©版权所有 ©2017 CSpace - Powered by CSpace