Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode
Yin, Tanji1,2,3; Qin, Wei1
刊名SENSOR LETTERS
2013-03-01
卷号11期号:3页码:607-612
关键词Solid Contact Ion-Selective Electrode Dopamine beta-Cyclodextrin
ISSN号1546-198X
通讯作者Yin, TJ (reprint author), Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China. tjyin@yic.ac.cn
产权排序[Yin, Tanji; Qin, Wei] Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China; [Yin, Tanji] Chinese Acad Sci, South China Sea Inst Oceanol, Guangzhou 510301, Guangdong, Peoples R China; [Yin, Tanji] Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
英文摘要A simple solid-contact polymeric membrane ion-selective electrode for determination of dopamine was developed. The electrode is fabricated with polymeric membranes incorporating heptakis(2,3,6-tri-o-methyl)-beta-cyclodextrin as ionophore and sodium trakis[3,5-bis(trifluoromethyl)phenyl]borate as ionic additive. Using hydrophobic poly(3-octylthiophene) as solid-contact transducer, the sensor displays a stable potential response for detection of dopamine in 2 mM HAc-NaAc buffer solution (pH 4.4) within a wide concentration range of 3.0 x 10(-5) M-1.0 x 10(-3) M with a sub-Nernstian slope of 43.8 +/- 0.5 mV/dec. The detection limit calculated as the intersection of the two slope lines is 1.3 x 10(-5) M. The electrode exhibits good selectivity over inorganic ions, pharmaceutical excipients and ascorbic acid. In addition, the electrode shows a stable potential response over a wide pH range of 4.0 to 8.5, fast response time (less than 10 s) and excellent repeatability. The proposed electrode has been successfully applied for direct potentiometric determination of dopamine in pharmaceutical formulation without pretreatment procedures.
学科主题Chemistry, Analytical ; Electrochemistry ; Instruments & Instrumentation ; Physics, Applied
研究领域[WOS]Chemistry ; Electrochemistry ; Instruments & Instrumentation ; Physics
关键词[WOS]FLOW-INJECTION ANALYSIS ; SPECTROPHOTOMETRIC DETERMINATION ; CHEMILUMINESCENCE DETECTION ; PHARMACEUTICAL-PREPARATIONS ; ASCORBIC-ACID ; CATECHOLAMINES ; CARRIERS ; SENSORS
收录类别SCI
资助信息Outstanding Youth Natural Science Foundation of Shandong Province [JQ200814]; National Natural Science Foundation of China [20977073]; Taishan Scholar Program of Shandong Province [TS20081159]
原文出处http://dx.doi.org/10.1166/sl.2013.2914
语种英语
WOS记录号WOS:000323236200028
公开日期2014-07-08
内容类型期刊论文
源URL[http://ir.yic.ac.cn/handle/133337/6988]  
专题烟台海岸带研究所_中科院海岸带环境过程与生态修复重点实验室
作者单位1.Chinese Acad Sci, Key Lab Coastal Zone Environm Proc & Ecol Remedia, Shandong Prov Key Lab Coastal Zone Environm Proc, Yantai Inst Coastal Zone Res YIC,YICCAS, Yantai 264003, Shandong, Peoples R China
2.Chinese Acad Sci, South China Sea Inst Oceanol, Guangzhou 510301, Guangdong, Peoples R China
3.Chinese Acad Sci, Grad Sch, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Yin, Tanji,Qin, Wei. Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode[J]. SENSOR LETTERS,2013,11(3):607-612.
APA Yin, Tanji,&Qin, Wei.(2013).Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode.SENSOR LETTERS,11(3),607-612.
MLA Yin, Tanji,et al."Potentiometric Determination of Dopamine Using a Solid-Contact Polymeric Membrane Ion-Selective Electrode".SENSOR LETTERS 11.3(2013):607-612.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace