A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand
Liu CY ; Zhao HJ ; Gao S ; Jia JB ; Zhao LM ; Yong DM ; Dong SJ
刊名biosensors & bioelectronics
2013
卷号45页码:213-218
关键词WATER PROCESS-CONTROL WASTE-WATER BOD SENSOR BIOSENSOR FERRICYANIDE TOXICITY SYSTEM CELLS ASSAY FILM
ISSN号0956-5663
通讯作者zhao hj
中文摘要we reported a reagent-free tubular biofilm reactor (bfr) based analytical system for rapid online biochemical oxygen demand (bud) determination. the bfr was cultivated using microbial seeds from activated sludge. it only needs tap water to operate and does not require any chemical reagent. the analytical performance of this reagent-free bfr system was found to be equal to or better than the bfr system operated using phosphate buffer saline (pbs) and high purity deionized water. the system can readily achieve a limit of detection of 0.25 mg o-2 l-1, possessing superior reproducibility, and longterm operational and storage stability. more importantly, we confirmed for the first time that the bfr system is capable of tolerating common toxicants found in wastewaters, such as 3,5-dichlorophenol and zn(ii), cr(vi), cd(ii), cu(ii), pb(ii), mn(ii) and ni(ii), enabling the method to be applied to a wide range of wastewaters. the sloughing and clogging are the important attributes affecting the operational stability, hence, the reliability of most online wastewater monitoring systems, which can be effectively avoided, benefiting from the tubular geometry of the reactor and high flow rate conditions. these advantages, coupled with simplicity in device, convenience in operation and minimal maintenance, make such a reagent-free bfr analytical system promising for practical bud online determination. (c) 2013 elsevier b.v. all rights reserved.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000317888600035
公开日期2014-04-15
内容类型期刊论文
源URL[http://ir.ciac.jl.cn/handle/322003/49737]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Liu CY,Zhao HJ,Gao S,et al. A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand[J]. biosensors & bioelectronics,2013,45:213-218.
APA Liu CY.,Zhao HJ.,Gao S.,Jia JB.,Zhao LM.,...&Dong SJ.(2013).A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand.biosensors & bioelectronics,45,213-218.
MLA Liu CY,et al."A reagent-free tubular biofilm reactor for on-line determination of biochemical oxygen demand".biosensors & bioelectronics 45(2013):213-218.