Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS | |
Cheng, Xuansheng1,2; Jing, Wei1,2; Li, Xinlei1; Lu, Changde3 | |
刊名 | Earthquake and Structures |
2018-08-01 | |
卷号 | 15期号:2页码:133-144 |
关键词 | Bars (metal) Dynamic response Liquid sloshing Seismic response Springs (components) Structural dynamics Isolated structures Liquid storage Nonlinear characteristics Response reductions Shaking table tests Sliding isolation Steel bars Wave heights |
ISSN号 | 20927614 |
DOI | 10.12989/eas.2018.15.2.133 |
英文摘要 | To study the effectiveness of sliding isolation in a CRLSS (concrete rectangular liquid-storage structure) and develop a reasonable limiting-device method, dynamic responses of non-isolation, sliding isolation with spring limiting-devices and sliding isolation with steel bar limiting-devices are comparatively studied by shaking table test. The seismic response reduction advantage of sliding isolation for concrete liquid-storage structures is discussed, and the effect of the limiting-device type on system dynamic responses is analyzed. The results show that the dynamic responses of sliding isolation CRLSS with steel bar-limiting devices are significantly smaller than that of sliding isolation CRLSS with spring-limiting devices. The structure acceleration and liquid sloshing wave height are greatly influenced by spring-limiting devices. The acceleration of the structure in this case is close to or greater than that of a non-isolated structure. Liquid sloshing shows stronger nonlinear characteristics. On the other hand, sliding isolation with steel bar-limiting devices has a good control effect on the structural dynamic response and the liquid sloshing height simultaneously. Thus, a limiting device is an important factor affecting the seismic response reduction effect of sliding isolation. To take full advantage of sliding isolation in a concrete liquid-storage structure, a reasonable design of the limiting device is particularly important. © 2018 Techno-Press, Ltd. |
WOS研究方向 | Engineering |
语种 | 英语 |
出版者 | Techno-Press |
WOS记录号 | WOS:000442693500003 |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/150567] |
专题 | 土木工程学院 |
作者单位 | 1.Key Laboratory of Disaster Prevention and Mitigation in Civil Engineering of Gansu Province, Lanzhou University of Technology, Lanzhou; 730050, China; 2.Western Eng. Research Center of Disaster Mitigation in Civil Eng. of Ministry of Education, Lanzhou University of Technology, Lanzhou; 730050, China; 3.The Second Engineering Co., LTD, China Railway 21 Bureau Group Co., LTD, Lanzhou; 730070, China |
推荐引用方式 GB/T 7714 | Cheng, Xuansheng,Jing, Wei,Li, Xinlei,et al. Effect of the limiting-device type on the dynamic responses of sliding isolation in a CRLSS[J]. Earthquake and Structures,2018,15(2):133-144. |