Structure design of the shutter with slider-crank mechanism
Jiaqi, Fei
2022-01-14
会议日期2022-01-14
会议地点Virtual, Online, China
DOI10.1145/3517077.3517119
页码118-123
英文摘要

In order to realize the miniaturization and lightweight of the infrared nonuniform correction shutter, the crank slider mechanism is used to design. Firstly, the shutter blade is used as the slider and the driving mechanism is used as the crank, and the motion analysis is carried out. The transmission angle of the crank slider mechanism is calculated to be no less than 66.42 °. Then, the slider, connecting rod and crank are analyzed respectively, the force system and motion equation are established, and the driving torque of the shutter is calculated. The design results show that the volume, weight and driving torque of the same target product are reduced by 1 / 3, 1 / 2 and 1 / 2, respectively, compared with the direct motion rotary shutter commonly used in nonuniform correction of infrared camera. The design goal is achieved. © 2022 Owner/Author.

产权排序1
会议录ICMIP 2022 - Proceedings of 2022 7th International Conference on Multimedia and Image Processing
会议录出版者Association for Computing Machinery
语种英语
内容类型会议论文
源URL[http://ir.opt.ac.cn/handle/181661/96009]  
专题西安光学精密机械研究所_动态光学成像研究室
通讯作者Jiaqi, Fei
作者单位Laboratory of Aircraft Optical Imaging Monitoring and Measurement Technology, Xi'An Institute of Optics and Precision Mechanics of CAS, China
推荐引用方式
GB/T 7714
Jiaqi, Fei. Structure design of the shutter with slider-crank mechanism[C]. 见:. Virtual, Online, China. 2022-01-14.