The Measurement of PSF Ellipticity of an Unobstructed Off-Axis Space Telescope: Error Analysis
K. Fan; J. Luo; X. He; C. Li and X. Zhang
刊名IEEE Access
2021
卷号9页码:120730-120743
ISSN号21693536
DOI10.1109/ACCESS.2021.3108638
英文摘要It is an effective method to detect weak gravitational lensing (WL) in the universe by measuring ellipticities of galaxies via astronomical telescopes. Optical properties of telescopes are critical to WL detections. To ensure the used telescopes to be competent, it is necessary to measure point spread function (PSF) ellipticities of telescopes in labs. In this paper, a way based on simulated star target imaging is proposed to measure PSF ellipticity of an unobstructed off-axis space telescope. Related errors are identified and modeled carefully for the first time. Effects of detector noises, micro-vibration of optical platforms, defocusing of simulated star target, wavefront errors (WFEs) and central obstructions of collimators on PSF ellipticity measurements of the telescope are analyzed. Results show that the measurement error of PSF ellipticity decreases from 0.0105 to 0.0043 by adopting 10 iterations of the iterative weighted centroiding algorithm when SNRs are under 24 dB. To ensure PSF ellipticity measurement errors are not larger than 0.01, the micro-vibration angle of the optical platform should be less than 0.05''. When focal length of the collimator is twice that of the telescope, the measurement errors of PSF ellipticity are under 0.01 if the defocusing of simulated star target is controlled to be not larger than 0.1 mm. In addition, WFEs and central obstructions of collimators change PSF ellipticity measurement errors to different degrees at different fields of view (FOVs). Due to 20 nm RMS WFE of the collimator, the maximum value of PSF ellipticity measurement errors over full FOVs is 0.1 and the average value is 0.0269. If the radius of central obscuration of the collimator is 150 mm, the maximum measurement error of PSF ellipticity over full FOVs is 0.0091. According to the results shown in this paper, significant references for high accuracy measurements of PSF ellipticity of telescopes can be provided. 2013 IEEE.
URL标识查看原文
内容类型期刊论文
源URL[http://ir.ciomp.ac.cn/handle/181722/65403]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
K. Fan,J. Luo,X. He,et al. The Measurement of PSF Ellipticity of an Unobstructed Off-Axis Space Telescope: Error Analysis[J]. IEEE Access,2021,9:120730-120743.
APA K. Fan,J. Luo,X. He,&C. Li and X. Zhang.(2021).The Measurement of PSF Ellipticity of an Unobstructed Off-Axis Space Telescope: Error Analysis.IEEE Access,9,120730-120743.
MLA K. Fan,et al."The Measurement of PSF Ellipticity of an Unobstructed Off-Axis Space Telescope: Error Analysis".IEEE Access 9(2021):120730-120743.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace