Research on Dispersive Detection Technology Based on Digital Micromirror Device by Atomic Fluorescence Spectrometry
Tao, C.; Li, C. S.; Wang, H. X.; Zhang, Y. R.; Zhao, C. W.; Zhou, Z. H.; Ma, Z. Y.; Tian, D.
刊名Chinese Journal of Analytical Chemistry
2018
卷号46期号:12页码:1878-1884
关键词Hydride generation atomic fluorescence spectrometry Dispersive detection Digital micro-mirror device UV digital micromirror spectrometer spectroscopy tube Chemistry
ISSN号0253-3820
DOI10.1016/s1872-2040(18)61128-4
英文摘要A ultraviolet (UV) digital micromirror spectrometer using a digital micromirror device (DMD) as a spatial light modulator, a grating as a spectroscope and a photomultiplier tube (PMT) as a detector, was specially designed for dispersive hydride generation atomic fluorescence spectrometry (HG-AFS). To improve the detection ability of the UV digital micromirror spectrometer for weak fluorescence signals at 180-320 nm, a high UV transmittance DMD was used and the signal acquisition system was improved, and the control parameters of DMD and PMT negative high voltage were optimized. The feasibility of the spectrometer was demonstrated with standard sample analyzing of As, Sb, Bi, and Hg, the emission and atomic fluorescence spectra were obtained, and the scattering interference caused by the light source was discussed. The results showed that the UV digital micromirror spectrometer had a preliminary ability for the excitation fluorescence analysis by HG-AFS. In addition, due to no macroscopic moving parts, the UV digital micromirror spectrometer had simple construction and fast analysis speed (0.848 s per spectrum scan).
内容类型期刊论文
源URL[http://ir.ciomp.ac.cn/handle/181722/61132]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
Tao, C.,Li, C. S.,Wang, H. X.,et al. Research on Dispersive Detection Technology Based on Digital Micromirror Device by Atomic Fluorescence Spectrometry[J]. Chinese Journal of Analytical Chemistry,2018,46(12):1878-1884.
APA Tao, C..,Li, C. S..,Wang, H. X..,Zhang, Y. R..,Zhao, C. W..,...&Tian, D..(2018).Research on Dispersive Detection Technology Based on Digital Micromirror Device by Atomic Fluorescence Spectrometry.Chinese Journal of Analytical Chemistry,46(12),1878-1884.
MLA Tao, C.,et al."Research on Dispersive Detection Technology Based on Digital Micromirror Device by Atomic Fluorescence Spectrometry".Chinese Journal of Analytical Chemistry 46.12(2018):1878-1884.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace