Optimization of focusing position in laser induced breakdown spectroscopy system based on quantitative analysis internal standard method of steel
Li, Zhicong2,3; Yang, Jianfeng3; Wang, Zhiyuan1,2; Zhao, Yiyi3; Huang, Shuaidong2,3; Liu, Shengrun2,3
2022
会议日期2021-12-07
会议地点Kunming, China
关键词Laser induced breakdown spectroscopy(LIBS) Quantitative analysis Focus position Detection sensitivity Limit of detection(LOD)
卷号12169
DOI10.1117/12.2627459
英文摘要

A laser induced breakdown spectroscopy (LIBS) system has many experimental key parameter factors. Focusing position in laser induced breakdown spectroscopy (LIBS) system is an experimental key parameter factor. The optimization of spectral intensity has been studied, but the results are often inaccurate. In this Letter, A quantitative analysis internal standard method was proposed to optimize the parameter of LIBS experimental system. One 100mm focusing lens and eight standard alloy steels with rich element content were employed as samples. By employing internal standard method, the minority elements (Mn, Cr, Cu) in steels were quantitatively analyzed and the element detection sensitivity was obtained. The limit of detection (LOD) of the minority elements under different focusing states was calculated, and finally the optimal focus position was obtained. The result which indirectly shows that the best laser focusing position of LIBS system with 100mm focusing lens is 6mm below the surface of samples, and the limit of detection (LOD) of the minority elements maintain the minimum value at this position (0.00159 wt.%), which indicates that the quantitative analysis method is effective and reliable for optimizing the parameters of LIBS system. © 2022 SPIE

产权排序1
会议录Eighth Symposium on Novel Photoelectronic Detection Technology and Applications
会议录出版者SPIE
语种英语
ISSN号0277786X;1996756X
ISBN号9781510653115
内容类型会议论文
源URL[http://ir.opt.ac.cn/handle/181661/95837]  
专题西安光学精密机械研究所_月球与深空探测技术研究室
通讯作者Yang, Jianfeng
作者单位1.Shanghai Institute of Optics and Fine Mechanics, The Chinese Academy of Sciences, Shanghai; 201800, China
2.School of Materials Science and Optoelectronic Technology, University of Chinese Academy of Sciences, Beijing; 100049, China;
3.Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China;
推荐引用方式
GB/T 7714
Li, Zhicong,Yang, Jianfeng,Wang, Zhiyuan,et al. Optimization of focusing position in laser induced breakdown spectroscopy system based on quantitative analysis internal standard method of steel[C]. 见:. Kunming, China. 2021-12-07.