Prevention of UF membrane fouling in drinking water treatment by addition of H2O2 during membrane backwashing
Yu, Wenzheng; Graham, Nigel; Liu, Ting
刊名WATER RESEARCH
2019-02-01
卷号149页码:394-405
关键词Water treatment Ultrafiltration Membrane fouling H2O2 Coagulation Biopolymers
ISSN号0043-1354
英文摘要Although conventional coagulation pre-treatment can mitigate the fouling of ultrafiltration (UF) membrane when treating raw waters, it is insufficient to restrict the development of irreversible fouling and reversible fouling to a low level. In this paper we demonstrate that the intermittent addition of H2O2 into the membrane tank during backwash events (after coagulation pre-treatment) successfully prevented the development of any significant membrane fouling. Laboratory-scale tests were undertaken using two membrane systems operated in parallel over 60 days, one serving as a reference coagulation-ultrafiltration (CUF) process, and the other receiving the H2O2 (CUF-H2O2), with a decreasing dose in three successive phases: 10, 5 and 2 mg/L. The results showed that the addition of H2O2 (via a separate dosing tube) during a 1 min backwash process (at 30 min intervals) reduced the growth of bacteria in the membrane tank, and the associated concentrations of soluble microbial products (SMP, including protein and polysaccharide). This resulted in a much reduced cake layer, which contained significantly less high MW organic matter (>50%), such as EPS, thereby improving the interaction between particles in the cake layer and/or particles and the membrane surface. There was also less organic matter, of all MW fractions, adsorbed in the membrane pores of the CUF-H2O2 system. The addition of H2O2 in the membrane tank appeared to alter the nature of the organic matter with a conversion of hydrophobic to hydrophilic fractions, which induced less organics adsorption within the hydrophobic PVDF membrane pores, and a reduced bonding ability for particles. There was no physico-chemical evidence of any deterioration of the membrane from exposure to H2O2, which indicates the feasibility of applying this novel method of fouling control for full-scale UF based water treatment processes. (C) 2018 Elsevier Ltd. All rights reserved.
内容类型期刊论文
源URL[http://ir.rcees.ac.cn/handle/311016/43509]  
专题生态环境研究中心_中国科学院饮用水科学与技术重点实验室
作者单位1.Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
2.Imperial Coll London, Dept Civil & Environm Engn, South Kensington Campus, London SW7 2AZ, England
推荐引用方式
GB/T 7714
Yu, Wenzheng,Graham, Nigel,Liu, Ting. Prevention of UF membrane fouling in drinking water treatment by addition of H2O2 during membrane backwashing[J]. WATER RESEARCH,2019,149:394-405.
APA Yu, Wenzheng,Graham, Nigel,&Liu, Ting.(2019).Prevention of UF membrane fouling in drinking water treatment by addition of H2O2 during membrane backwashing.WATER RESEARCH,149,394-405.
MLA Yu, Wenzheng,et al."Prevention of UF membrane fouling in drinking water treatment by addition of H2O2 during membrane backwashing".WATER RESEARCH 149(2019):394-405.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace