Biological evaluation of running waters in Korea, with special reference to bioassessment using the PFU system | |
Chung, PR; Cho, KS; Jung, YH; Shen, YF; Gu, MR; Feng, WS | |
刊名 | HYDROBIOLOGIA |
1998 | |
卷号 | 390期号:1-3页码:107-115 |
关键词 | freshwater protozoans water quality assessment polyurethane foam unit Han River system of Korea |
ISSN号 | 0018-8158 |
通讯作者 | Chung, PR, Inha Univ, Coll Med, Dept Parasitol, Inchon, South Korea |
中文摘要 | A total of six stations in the Han River system were selected for establishing polyurethane foam units (PFUs) to collect protozoans, including phytomastigophorans, zoomastigophorans, amoebas and ciliates, in July 1993. In the bioassessment of microbial communities using the PFUs, the number of species decreased as pollution intensity increased. The diversity index values calculated at the main stations generally agreed with the pollution status of the stations. Anyang-Chon (Chon means stream) showed the lowest diversity value (1.89), and all stations, except Masok and Anyang-Chon, showed diversity index values ranging from 3.15 to 3.93. The highest heterotrophic index (HI) value was detected in Anyang-Chon followed by Masok-Chon. The number of species at the main stations reached a maximum on day 11 of being exposed to PFUs. The results of S-eq, G and T-90% all suggest that bioassessments using the PFU system were well matched with pollution status of the water. All microbial variables were significantly correlated with comprehensive chemical pollution indices, P-a and P-b, with correlation coefficients ranging from r=0.87 to r=0.96. |
英文摘要 | A total of six stations in the Han River system were selected for establishing polyurethane foam units (PFUs) to collect protozoans, including phytomastigophorans, zoomastigophorans, amoebas and ciliates, in July 1993. In the bioassessment of microbial communities using the PFUs, the number of species decreased as pollution intensity increased. The diversity index values calculated at the main stations generally agreed with the pollution status of the stations. Anyang-Chon (Chon means stream) showed the lowest diversity value (1.89), and all stations, except Masok and Anyang-Chon, showed diversity index values ranging from 3.15 to 3.93. The highest heterotrophic index (HI) value was detected in Anyang-Chon followed by Masok-Chon. The number of species at the main stations reached a maximum on day 11 of being exposed to PFUs. The results of S-eq, G and T-90% all suggest that bioassessments using the PFU system were well matched with pollution status of the water. All microbial variables were significantly correlated with comprehensive chemical pollution indices, P-a and P-b, with correlation coefficients ranging from r=0.87 to r=0.96. |
学科主题 | Marine & Freshwater Biology |
WOS标题词 | Science & Technology ; Life Sciences & Biomedicine |
类目[WOS] | Marine & Freshwater Biology |
研究领域[WOS] | Marine & Freshwater Biology |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000080235900011 |
公开日期 | 2010-10-13 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihb.ac.cn/handle/152342/10194] |
专题 | 水生生物研究所_中科院水生所知识产出(2009年前)_期刊论文 |
作者单位 | 1.Inha Univ, Coll Med, Dept Parasitol, Inchon, South Korea 2.Korea Res Inst Ecosyst Conservat, Chunchon, South Korea 3.Acad Sinica, Inst Hydrobiol, Wuhan, Peoples R China |
推荐引用方式 GB/T 7714 | Chung, PR,Cho, KS,Jung, YH,et al. Biological evaluation of running waters in Korea, with special reference to bioassessment using the PFU system[J]. HYDROBIOLOGIA,1998,390(1-3):107-115. |
APA | Chung, PR,Cho, KS,Jung, YH,Shen, YF,Gu, MR,&Feng, WS.(1998).Biological evaluation of running waters in Korea, with special reference to bioassessment using the PFU system.HYDROBIOLOGIA,390(1-3),107-115. |
MLA | Chung, PR,et al."Biological evaluation of running waters in Korea, with special reference to bioassessment using the PFU system".HYDROBIOLOGIA 390.1-3(1998):107-115. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论