Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency
Zhao, Hui2; Mi, Jiao1,2; Yu, Congcong1,2; Ge, Rui1,2; Fan, Xuewu2
刊名Applied Optics
2019-12-10
卷号58期号:35页码:9562-9569
ISSN号1559128X;21553165
DOI10.1364/AO.58.009562
产权排序1
英文摘要Wave-front coding (WFC) is a well-known technique that can be used to extend the depth of field (DOF) of incoherent imaging systems. The phase masks make the optical transfer function drop significantly, and digital restoration must be used to obtain a clear image with a largely extended DOF. According to the existing literature, in order to obtain satisfactory restoration results, the optical modulation transfer function (MTF) at the Nyquist frequency is required to be bigger than 0.1, which has already become a popularly accepted design constraint. However, according to our experimental research reported in this paper, this requirement is overly strict. By assembling one already fabricated WFC lens and another camera having physically higher resolution, the MTF of the newly assembled WFC system used in the experimentation has quite a low response at its Nyquist frequency. The experimental results demonstrate that when the optical MTF value at the Nyquist frequency reaches the minimum value of about 0.05, visually satisfactory restoration results can still be obtained as long as the MTF is optimized to be highly insensitive to defocus and the corresponding SNR of the coded intermediate images goes beyond 20 dB at the same time. The experimental results indicate that the overly strict constraint could be alleviated while designing a WFC system. © 2019 Optical Society of America.
语种英语
出版者OSA - The Optical Society
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/32075]  
专题西安光学精密机械研究所_空间光学应用研究室
通讯作者Zhao, Hui
作者单位1.University of Chinese Academy of Sciences, Beijing; 100049, China
2.Space Optics Lab, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710019, China;
推荐引用方式
GB/T 7714
Zhao, Hui,Mi, Jiao,Yu, Congcong,et al. Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency[J]. Applied Optics,2019,58(35):9562-9569.
APA Zhao, Hui,Mi, Jiao,Yu, Congcong,Ge, Rui,&Fan, Xuewu.(2019).Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency.Applied Optics,58(35),9562-9569.
MLA Zhao, Hui,et al."Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency".Applied Optics 58.35(2019):9562-9569.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace