Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography | |
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro | |
刊名 | JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES |
2011 | |
卷号 | 879期号:32页码:3802-3805 |
关键词 | Centrifugal counter-current chromatography Figure-8 column Protein separation Polymer phase system Lysozyme Myoglobin Hollow fiber membrane dialyzer |
ISSN号 | 15700232 |
英文摘要 | The performance of protein separation using the figure-8 column configuration in centrifugal countercurrent chromatography was investigated under various flow rates and revolution speeds. The separation was performed with a two-phase solvent system composed of polyethylene glycol 1000/potassium phosphate each at 12.5% (w/w) in water and with lysozyme and myoglobin as test samples. In order to improve tracing of the elution curve, a hollow fiber membrane dialyzer was inserted at the inlet of the UV detector. The results showed that the retention of stationary phase (Sf) and resolution (Rs) increased with decreased flow rate and increased revolution speed. The highest Rs of approximately 1 was obtained at a flow rate of 0.01 mL/min under a revolution speed of 1200 rpm with a 3.4 mL capacity column. |
学科主题 | Biochemistry & Molecular Biology ; Chemistry |
WOS记录号 | WOS:000298530200004 |
公开日期 | 2012-11-29 |
内容类型 | 期刊论文 |
源URL | [http://ir.xjipc.cas.cn/handle/365002/1449] |
专题 | 新疆理化技术研究所_省部共建新疆特有药用资源利用重点实验室 |
作者单位 | NHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China |
推荐引用方式 GB/T 7714 | Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography[J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,2011,879(32):3802-3805. |
APA | Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2011).Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,879(32),3802-3805. |
MLA | Yang Yi,et al."Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 879.32(2011):3802-3805. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论