CORC  > 大连理工大学
A simplified indoor wet-bulb globe temperature formula to determine acceptable hot environmental parameters in naturally ventilated buildings
Gao, Jie; Wang, Yi; Wu, Xiaozhou; Gu, Xianghong; Song, Xiaocheng
刊名ENERGY AND BUILDINGS
2019
卷号196页码:169-177
关键词Naturally ventilated building Hot environment Indoor wet-bulb globe temperature Natural wet-bulb temperature Globe temperature
ISSN号0378-7788
URL标识查看原文
WOS记录号[DB:DC_IDENTIFIER_WOSID]
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/3216290
专题大连理工大学
作者单位1.Dalian Univ, Coll Civil Engn & Architecture, Dalian, Peoples R China.
2.Xian Univ Architecture & Technol, State Key Lab Green Bldg Western China, Xian, Shaanxi, Peoples R China.
3.Dalian Univ Technol, Sch Civil Engn, Dalian, Peoples R China.
推荐引用方式
GB/T 7714
Gao, Jie,Wang, Yi,Wu, Xiaozhou,et al. A simplified indoor wet-bulb globe temperature formula to determine acceptable hot environmental parameters in naturally ventilated buildings[J]. ENERGY AND BUILDINGS,2019,196:169-177.
APA Gao, Jie,Wang, Yi,Wu, Xiaozhou,Gu, Xianghong,&Song, Xiaocheng.(2019).A simplified indoor wet-bulb globe temperature formula to determine acceptable hot environmental parameters in naturally ventilated buildings.ENERGY AND BUILDINGS,196,169-177.
MLA Gao, Jie,et al."A simplified indoor wet-bulb globe temperature formula to determine acceptable hot environmental parameters in naturally ventilated buildings".ENERGY AND BUILDINGS 196(2019):169-177.