Design of a non-intercepting beam diagnostic device using neutral beam fluorescence method
Ren, H.T.1; Ren, H.T. (htren@pku.edu.cn); Sun, L.T.2; Zhao, H.W.2; Chen, J.E.1; Guo, Z.Y.1; Zhang, T.1; Xu, Y.1; Chen, J.1; Zhang, A.L.1
2013
会议日期IPAC 2013, May 12, 2013 - May 17, 2013
会议地点IPAC
页码547-549
英文摘要The forward neutral beam from deflecting magntic field carries some characteristic properties of high intensity particle beams, such as profile, emittance etc. Therefore a reliable measurement of neutral beam fluorescence can be used to develop a fast and non-interceptive beam diagnostic tool. A non-intercepting beam emittance (profile) monitor using neutral beam fluorescence method has being constructed at Peking University. The monitor isdesigned to measure the transverse emittance in both directions on a low energy intense proton beams at the ion source (IS) test bench. The neutralparticles are produced in the space charge compensation (SCC) zone. The mechanical design has been completed. The implementation, measurement, and comparison to multi-slit singlewire type emittance monitor will be carried out in the near future. The details of design and some preliminary results ofmeasurement will be presented in this paper. Copyright © 2013 by JACoW.(12 refs)
会议录IPAC 2013: Proceedings of the 4th International Particle Accelerator Conference
语种英语
内容类型会议论文
源URL[http://ir.impcas.ac.cn/handle/113462/23587]  
专题近代物理研究所_兰州重离子研究装置
通讯作者Ren, H.T. (htren@pku.edu.cn)
作者单位1.State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871, China
2.Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
推荐引用方式
GB/T 7714
Ren, H.T.,Ren, H.T. ,Sun, L.T.,et al. Design of a non-intercepting beam diagnostic device using neutral beam fluorescence method[C]. 见:. IPAC. IPAC 2013, May 12, 2013 - May 17, 2013.