TL response of LiF:Mg,Cu,P (GR200A and GR207A) exposed to high-energy C-12 ions
Ma, F.; Ge, H. L.; Zhang, Y. B.; Wan, B.; Li, Y. Y.; Mao, W.; Xu, X. W.; Zhang, X. Y.; Chen, L.; Luo, P.
刊名RADIATION MEASUREMENTS
2015-07-01
卷号78页码:23-27
关键词Thermoluminescent detectors GR200A and GR207A High-energy C-12 ions Dose response Thermoluminescent efficiency
ISSN号1350-4487
DOI10.1016/j.radmeas.2014.10.004
英文摘要The characteristics of (LiF)-Li-nat.,7:Mg,Cu,P thermoluminescent detectors exposed to high-energy C-12 (165 MeV/nucleon) ions and Co-66 gamma-rays have been investigated. Through a careful analysis of the glow curves by the GlowFit program, it is found that the relative amplitude of satellite peaks 3, 5, 6 and 7 to peak 4, measured after irradiated with high-energy C-12 ions, is higher than that with Co-60 gamma-rays for both types of TL, detectors. It is observed that "(LiF)-Li-nat.,7:Mg,Cu,P thermoluminescent detectors would also exhibit a good linear dose response when the delivered dose of high-energy C-12 ions is in the range from 100 mGy to 1600 mGy. Furthermore, the relative efficiency of the (LiF)-Li-nat.,7:Mg,Cu,P thermoluminescent detectors is independent of the absorbed dose in the linear dose response range. Compared to previously published data, the relative efficiency of the (LiF)-Li-7:Mg,Cu,P TL detectors decreases with increasing LET values. (C) 2014 Elsevier Ltd. All rights reserved.
资助项目National Natural Science Foundation of China[91226107] ; National Natural Science Foundation of China[11305229] ; National Natural Science Foundation of China[11105186] ; Strategic Priority Research Program of the Chinese Academy of Sciences[XDA03030300]
WOS关键词TRACK STRUCTURE-THEORY ; THERMOLUMINESCENT DETECTORS ; RELATIVE EFFICIENCY ; LIF-MG,CU,P ; RADIATION ; LIF ; DOSIMETRY ; PARTICLE ; BEAMS
WOS研究方向Nuclear Science & Technology
语种英语
出版者PERGAMON-ELSEVIER SCIENCE LTD
WOS记录号WOS:000356747500004
资助机构National Natural Science Foundation of China ; Strategic Priority Research Program of the Chinese Academy of Sciences
内容类型期刊论文
源URL[http://119.78.100.186/handle/113462/40054]  
专题近代物理研究所_实验物理中心
通讯作者Chen, L.
作者单位Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
推荐引用方式
GB/T 7714
Ma, F.,Ge, H. L.,Zhang, Y. B.,et al. TL response of LiF:Mg,Cu,P (GR200A and GR207A) exposed to high-energy C-12 ions[J]. RADIATION MEASUREMENTS,2015,78:23-27.
APA Ma, F..,Ge, H. L..,Zhang, Y. B..,Wan, B..,Li, Y. Y..,...&Zhang, H. B..(2015).TL response of LiF:Mg,Cu,P (GR200A and GR207A) exposed to high-energy C-12 ions.RADIATION MEASUREMENTS,78,23-27.
MLA Ma, F.,et al."TL response of LiF:Mg,Cu,P (GR200A and GR207A) exposed to high-energy C-12 ions".RADIATION MEASUREMENTS 78(2015):23-27.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace