A new multi-strip ionization chamber used as online beam monitor for heavy ion therapy
Xu, Zhiguo1,2; Mao, Ruishi1; Duan, Limin1; She, Qianshun1; Hu, Zhengguo1; Li, He1; Lu, Ziwei1; Zhao, Qiecheng1; Yang, Herun1; Su, Hong1
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
2013-11-21
卷号729页码:895-899
关键词Ionization Chamber Beam Position Monitor Heavy Ion Therapy
ISSN号0168-9002
DOI10.1016/j.nima.2013.08.069
文献子类Article
英文摘要

A multi-strip ionization chamber has been built for precise and fast monitoring of the carbon beam spatial distribution at Heavy Ion Researched Facility of Lanzhou Cooling Storing Ring (HIRFL-CSR). All the detector's anode, cathode and sealed windows are made by 2 mu m aluminized Mylar film in order to minimize the beam lateral deflection. The sensitive area of the detector is (100 x 100) mm(2), with the anode segmented in 100 strips, and specialized front-end electronics has been developed for simplifying the data acquisition and quick feedback of the relevant parameters to beam control system. It can complete one single beam profile in 200 mu s. (C) 2013 Elsevier B.V. All rights reserved,

资助项目National Nature Science Foundation of China[11205223]
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics
语种英语
出版者ELSEVIER SCIENCE BV
WOS记录号WOS:000325753500111
内容类型期刊论文
源URL[http://119.78.100.186/handle/113462/48475]  
专题近代物理研究所_实验物理中心
中国科学院近代物理研究所
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Xu, Zhiguo,Mao, Ruishi,Duan, Limin,et al. A new multi-strip ionization chamber used as online beam monitor for heavy ion therapy[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2013,729:895-899.
APA Xu, Zhiguo.,Mao, Ruishi.,Duan, Limin.,She, Qianshun.,Hu, Zhengguo.,...&Zhang, Junwei.(2013).A new multi-strip ionization chamber used as online beam monitor for heavy ion therapy.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,729,895-899.
MLA Xu, Zhiguo,et al."A new multi-strip ionization chamber used as online beam monitor for heavy ion therapy".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 729(2013):895-899.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace