CORC  > 北京大学  > 工学院
Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro
Pan, J. ; Li, Y. L. ; Liu, C. M. ; Tian, Y. ; Yu, S. ; Wang, K. L. ; Zhang, J. ; Fang, J.
刊名PLASMA CHEMISTRY AND PLASMA PROCESSING
2017
关键词Cold atmospheric plasma-activated water Dental unit waterline system Biofilm Safety evaluation ENTEROCOCCUS-FAECALIS BACTERIAL-CONTAMINATION PRESSURE PLASMA INACTIVATION BIOFILM DISINFECTION ACID MICROORGANISMS DISCHARGES RESISTANCE
DOI10.1007/s11090-017-9811-0
英文摘要The disinfection of the inner surface of a medical device has long been a challenge for the central sterile supply departments. Dental unit waterline system (DUWLs) foster the attachment of microorganisms and development of biofilm, which lead to continuous contamination of the outlet water from dental units; this contamination may be responsible for a potential risk of infection due to the exposure of patients and medical staff. The present study investigated the disinfection effects of cold atmospheric plasma-activated water (CAPAW) on DUWLs using a model of 5-day-old Enterococcus faecalis biofilm. The results showed that the colony-forming unit was reduced from 10(7) to 0 after 5 min of treatment. The physicochemical properties of CAPAW were evaluated, including the pH value, oxidation reduction potential, and NO radical. The results showed that the inactivation mechanisms were mainly triggered by the reactive oxygen/nitrogen species. Additionally, CAPAW had a metal corrosion rate same as that of deionized water. We conclude that CAPAW can be applied as an appropriate alternative disinfectant against biofilm contamination of DUWLs.; 985 program of Peking University; Peking University; SCI(E); ARTICLE; 4; 1091-1103; 37
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/472472]  
专题工学院
推荐引用方式
GB/T 7714
Pan, J.,Li, Y. L.,Liu, C. M.,et al. Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro[J]. PLASMA CHEMISTRY AND PLASMA PROCESSING,2017.
APA Pan, J..,Li, Y. L..,Liu, C. M..,Tian, Y..,Yu, S..,...&Fang, J..(2017).Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro.PLASMA CHEMISTRY AND PLASMA PROCESSING.
MLA Pan, J.,et al."Investigation of Cold Atmospheric Plasma-Activated Water for the Dental Unit Waterline System Contamination and Safety Evaluation in Vitro".PLASMA CHEMISTRY AND PLASMA PROCESSING (2017).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace