CORC  > 北京大学  > 工学院
In vitro studies on silver implanted pure iron by metal vapor vacuum arc technique
Huang, Tao ; Cheng, Yan ; Zheng, Yufeng
刊名COLLOIDS AND SURFACES B-BIOINTERFACES
2016
关键词Pure iron Silver ion implantation Corrosion Biocompatibility FE-BASED ALLOYS STENTS BIOCOMPATIBILITY DEGRADATION CYTOTOXICITY COMPOSITES NANOPARTICLES BIOMATERIALS CORROSION SURFACE
DOI10.1016/j.colsurfb.2016.01.065
英文摘要Pure iron has been verified as a promising biodegradable metal for absorbable cardiovascular stent usage. However, the degradation rate of pure iron is too slow. To accelerate the degradation of the surface of pure iron, silver ions were implanted into pure iron by metal vapor vacuum arc (MEVVA) source at an extracted voltage of 40 keV. The implanted influence was up to 2 x 10(17) ions/cm(2). The composition and depth profiles, corrosion behavior and biocompatibility of Ag ion implanted pure iron were investigated. The implantation depths of Ag was around 60 nm. The element Ag existed as Ag2O in the outermost layer, then gradually transited to metal atoms in zero valent state with depth increase. The implantation of Ag ions accelerated the corrosion rate of pure iron matrix, and exhibited much more uniform corrosion behavior. For cytotoxicity assessment, the implantation of Ag ions slightly decreased the viability of all kinds of cell lines used in these tests. The hemolysis rate of Ag ion implanted pure iron was lower than 2%, which was acceptable, whereas the platelet adhesion tests indicated the implantation of Ag ions might increase the risk of thrombosis. (C) 2016 Elsevier B.V. All rights reserved.; National Basic Research Program of China (973 Program) [2012CB619102, 2012CB619100]; National Science Fund for Distinguished Young Scholars [51225101]; National Natural Science Foundation of China [51431002, 31170909]; NSFC/RGC Joint Research Scheme [51361165101]; State Key Laboratory for Mechanical Behavior of Materials [20141615]; Beijing Municipal Science and Technology Project [Z141100002814008]; SCI(E); EI; PubMed; ARTICLE; yfzheng@pku.edu.cn; 20-29; 142
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/434705]  
专题工学院
推荐引用方式
GB/T 7714
Huang, Tao,Cheng, Yan,Zheng, Yufeng. In vitro studies on silver implanted pure iron by metal vapor vacuum arc technique[J]. COLLOIDS AND SURFACES B-BIOINTERFACES,2016.
APA Huang, Tao,Cheng, Yan,&Zheng, Yufeng.(2016).In vitro studies on silver implanted pure iron by metal vapor vacuum arc technique.COLLOIDS AND SURFACES B-BIOINTERFACES.
MLA Huang, Tao,et al."In vitro studies on silver implanted pure iron by metal vapor vacuum arc technique".COLLOIDS AND SURFACES B-BIOINTERFACES (2016).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace