Research on magnetic center measurement of quadrupole and sextupole using vibrating wire alignment technique in HEPS-TF | |
Qu HM(屈化民); Li MX(李敏贤); Wu L(吴蕾); Gong LL(龚玲玲); Wu, Lei, Wang, Xiao-long, Li, Chun-hua, Qu, Hua-min, Wang, Zi-hao, Li, Min-xian; Li CH(李春华); Wang ZH(王梓豪); Wang XL(王小龙); Gong, Ling-ling | |
刊名 | RADIATION DETECTION TECHNOLOGY AND METHODS |
2018 | |
卷号 | 2018期号: 2页码: 50 |
ISSN号 | 2509-9930 |
DOI | 10.1007/s41605-018-0079-6 |
文献子类 | Article |
英文摘要 | In order to meet the extremely low emittance requirement, the magnets in the storage ring of high-energy photon source (HEPS) need to have a stable support and precise positioning. In HEPS-TF, the key and difficult technologies of HEPS should be researched and developed. Vibrating wire alignment technique is one important project of HEPS-TF. It can be used to pre-align the quadrupoles and sextupoles on one girder with high precision. A vibrating wire measurement system was set up and tested to verify the magnetic center measurement precision and the magnet adjustment error. |
电子版国际标准刊号 | 2509-9949 |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/286760] |
专题 | 高能物理研究所_加速器中心 |
通讯作者 | Wu L(吴蕾) |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Qu HM,Li MX,Wu L,et al. Research on magnetic center measurement of quadrupole and sextupole using vibrating wire alignment technique in HEPS-TF[J]. RADIATION DETECTION TECHNOLOGY AND METHODS,2018,2018( 2): 50. |
APA | 屈化民.,李敏贤.,吴蕾.,龚玲玲.,Wu, Lei, Wang, Xiao-long, Li, Chun-hua, Qu, Hua-min, Wang, Zi-hao, Li, Min-xian.,...&Gong, Ling-ling.(2018).Research on magnetic center measurement of quadrupole and sextupole using vibrating wire alignment technique in HEPS-TF.RADIATION DETECTION TECHNOLOGY AND METHODS,2018( 2), 50. |
MLA | 屈化民,et al."Research on magnetic center measurement of quadrupole and sextupole using vibrating wire alignment technique in HEPS-TF".RADIATION DETECTION TECHNOLOGY AND METHODS 2018. 2(2018): 50. |