Measurement of the transfer function for a spoke cavity of C-ADS Injector I | |
Lin, HY![]() ![]() ![]() ![]() ![]() ![]() | |
刊名 | CHINESE PHYSICS C中国物理. C
![]() |
2017 | |
卷号 | 41期号:4页码:47001 |
关键词 | Spoke012 Lorentz transfer function piezo fast tuner transfer function mechanical eigenmodes |
ISSN号 | 1674-1137 |
DOI | 10.1088/1674-1137/41/4/047001 |
文献子类 | Article |
英文摘要 | The spoke cavities mounted in the China Accelerator Driven sub-critical System (C-ADS) have high quality factor (Q) and very small bandwidth, making them very sensitive to mechanical perturbations, whether external or self-induced. The transfer function is used to characterize the response of the cavity eigenfrequency to the perturbations. This paper describes a method to measure the transfer function of a spoke cavity. The measured Lorentz transfer function shows there are 206 Hz and 311 Hz mechanical eigenmodes excited by Lorentz force in the cavity of C-ADS, and the measured piezo fast tuner transfer function shows there are 12 mechanical eigenmodes from 0 to 500 Hz. According to these results, some effective measures have been taken to weaken the influence of helium pressure fluctuation, avoid mechanical resonances and improve the reliability of the RF system. |
WOS研究方向 | Physics |
语种 | 英语 |
CSCD记录号 | CSCD:5954043 |
WOS记录号 | WOS:000400124800022 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/284747] ![]() |
专题 | 高能物理研究所_加速器中心 高能物理研究所_实验物理中心 高能物理研究所_多学科研究中心 |
作者单位 | 中国科学院高能物理研究所 |
推荐引用方式 GB/T 7714 | Lin, HY,Wang QY,Liu R,et al. Measurement of the transfer function for a spoke cavity of C-ADS Injector I[J]. CHINESE PHYSICS C中国物理. C,2017,41(4):47001. |
APA | Lin, HY.,王群要.,刘熔.,林海英.,王牧源.,...&王光伟.(2017).Measurement of the transfer function for a spoke cavity of C-ADS Injector I.CHINESE PHYSICS C中国物理. C,41(4),47001. |
MLA | Lin, HY,et al."Measurement of the transfer function for a spoke cavity of C-ADS Injector I".CHINESE PHYSICS C中国物理. C 41.4(2017):47001. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论