Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance | |
Ma, Wei1; Chen, Wei1; Qiao, Ruirui2; Liu, Chunyan2; Yang, Chunhui2; Li, Zhuokun1; Xu, Dinghua1; Peng, Chifang1; Jin, Zhengyu1; Xu, Chuanlai1 | |
刊名 | BIOSENSORS & BIOELECTRONICS |
2009-09-15 | |
卷号 | 25期号:1页码:240-243 |
关键词 | Detection Microcystin Immunosensor Nuclear Magnetic Resonance Sensitive Magnetic Nanoparticles |
ISSN号 | 0956-5663 |
DOI | 10.1016/j.bios.2009.06.020 |
英文摘要 | A stable and sensitive toxin residues immunosensor based on the relaxation of magnetic nanoparticles was developed. The method was performed in one reaction and offered sensitive, fast detection of target toxin residues in water. The target analyte, microcystin-LR (MC-LR) in Tai lake water, competed with the antigens on the surface of the magnetic nanoparticles and then influenced the formation of aggregates of the magnetic nanoparticles. Accordingly, the magnetic relaxation time of the magnetic nanoparticles was changed under the effect of the target analyte. The calibration curve was deduced at different concentrations of the target analyte. The limit of detection (LOD) of MC-LR was 0.6 ng g(-1) and the detection range was 1-18 ng g(-1). Another important feature of the developed method was the easy operation: only two steps were needed (1) to mix the magnetic nanoparticle solution with the sample solution and (2) read the results through the instrument. Therefore, the developed method may be a useful tool for toxin residues sensing and may find widespread applications. (C) 2009 Elsevier B.V. All rights reserved. |
语种 | 英语 |
出版者 | ELSEVIER ADVANCED TECHNOLOGY |
WOS记录号 | WOS:000270538400039 |
内容类型 | 期刊论文 |
源URL | [http://ir.iccas.ac.cn/handle/121111/67883] |
专题 | 中国科学院化学研究所 |
通讯作者 | Xu, Chuanlai |
作者单位 | 1.Jiangnan Univ, Sch Food Sci & Technol, Wuxi 214122, Jiangsu Prov, Peoples R China 2.Chinese Acad Sci, Inst Chem, Beijing 10008, Peoples R China |
推荐引用方式 GB/T 7714 | Ma, Wei,Chen, Wei,Qiao, Ruirui,et al. Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance[J]. BIOSENSORS & BIOELECTRONICS,2009,25(1):240-243. |
APA | Ma, Wei.,Chen, Wei.,Qiao, Ruirui.,Liu, Chunyan.,Yang, Chunhui.,...&Wang, Libing.(2009).Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance.BIOSENSORS & BIOELECTRONICS,25(1),240-243. |
MLA | Ma, Wei,et al."Rapid and sensitive detection of microcystin by immunosensor based on nuclear magnetic resonance".BIOSENSORS & BIOELECTRONICS 25.1(2009):240-243. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论