A simple and accurate method for determining accurately dissolved inorganic carbon in seawaters | |
Song, JM; Li, XG; Li, N; Gao, XL; Yuan, HM; Zhan, TR | |
刊名 | CHINESE JOURNAL OF ANALYTICAL CHEMISTRY |
2004-12-01 | |
卷号 | 32期号:12页码:1689-1692 |
关键词 | Dissolved Inorganic Carbon Seawater Titrimetry Jiaozhou Bay |
ISSN号 | 0253-3820 |
文献子类 | Article |
英文摘要 | Dissolved inorganic carbon (DIC) account for more than 95% of total carbon in seawater, so it is necessary to make reliable and precise measurements of DIC to study marine carbon cycling. In order to establish a simple and speed method, an airproof device of gas extraction-absorption was designed. Finally a simple method was developed for the determination of DIC in seawater through a large mount of experiments. The determination procedure is as follows: 100 similar to 150 mL seawater was put into conical flask, then add 10% H3PO4, the DIC in seawater sample was dissolved to form CO2 gas and carried by pure N-2, then the CO2 gas was absorbed by two grades 0.1 mol/L NaOH solution. Finally the absorbed solution was titrated by HCl standard solution of 0.01000 mol/L with the end points detected with the indicator phenolphthalein and bromocresol green-methyl red mixture. The precision and accuracy of the method were satisfied. This method was used to analyse seawater samples from Jiaozhou bay in June, 2003. The result shows that the average DIC in surface seawater is 2066 mumol/L, DIC in bottom seawater is 2075 mumol/L inside bay, but the average DIC in surface seawater is 1949 mumol/L, DIC in bottom seawater is 2147 mumol/L outside bay.; Dissolved inorganic carbon (DIC) account for more than 95% of total carbon in seawater, so it is necessary to make reliable and precise measurements of DIC to study marine carbon cycling. In order to establish a simple and speed method, an airproof device of gas extraction-absorption was designed. Finally a simple method was developed for the determination of DIC in seawater through a large mount of experiments. The determination procedure is as follows: 100 similar to 150 mL seawater was put into conical flask, then add 10% H3PO4, the DIC in seawater sample was dissolved to form CO2 gas and carried by pure N-2, then the CO2 gas was absorbed by two grades 0.1 mol/L NaOH solution. Finally the absorbed solution was titrated by HCl standard solution of 0.01000 mol/L with the end points detected with the indicator phenolphthalein and bromocresol green-methyl red mixture. The precision and accuracy of the method were satisfied. This method was used to analyse seawater samples from Jiaozhou bay in June, 2003. The result shows that the average DIC in surface seawater is 2066 mumol/L, DIC in bottom seawater is 2075 mumol/L inside bay, but the average DIC in surface seawater is 1949 mumol/L, DIC in bottom seawater is 2147 mumol/L outside bay. |
学科主题 | Chemistry, Analytical |
语种 | 英语 |
WOS记录号 | WOS:000226245500030 |
公开日期 | 2010-12-22 |
内容类型 | 期刊论文 |
源URL | [http://ir.qdio.ac.cn/handle/337002/2741] |
专题 | 海洋研究所_海洋生态与环境科学重点实验室 海洋研究所_海洋地质与环境重点实验室 |
作者单位 | 1.Chinese Acad Sci, Inst Oceanol, Qingdao 266071, Peoples R China 2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Song, JM,Li, XG,Li, N,et al. A simple and accurate method for determining accurately dissolved inorganic carbon in seawaters[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2004,32(12):1689-1692. |
APA | Song, JM,Li, XG,Li, N,Gao, XL,Yuan, HM,&Zhan, TR.(2004).A simple and accurate method for determining accurately dissolved inorganic carbon in seawaters.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,32(12),1689-1692. |
MLA | Song, JM,et al."A simple and accurate method for determining accurately dissolved inorganic carbon in seawaters".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 32.12(2004):1689-1692. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。