CORC  > 高能物理研究所
Calibration and monitoring of lhaaso-km2a muon detectors with muon decay events
Zuo, Xiong1,2; Xiao, Gang1; Feng, Shaohui1; Li, Xiurong1; Li, Cong1; Cheng, Ning1; Hong, Bin3; Chang, Jinfan1; Wang, Wei1; Gu, Minghao1
刊名Nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment
2018-01-21
卷号879页码:1-5
关键词Water cherenkov detector Calibration and monitoring Muon decay
ISSN号0168-9002
DOI10.1016/j.nima.2017.10.024
通讯作者Zuo, xiong(zuoxiong@ihep.ac.cn)
英文摘要The large high altitude air shower observatory (lhaaso) will be constructed at 4400 m asl in daocheng, sichuan province, with the aim of discovering sources of ultra-high energy cosmic rays and studying cosmic ray physics. the whole array includes 1171 muon detectors (mds), constituting the largest muon detector array in the world. the special high altitude and wide-field environment requires simple and stable calibration as well as monitoring method of mds. in this paper, the muon decay events will be selected for calibrating the charge and monitoring the water level of each md. in the prototype muon detector, the simulation and experiment results reveal that the charge of the decay electron is approximately 0.147 times that of the vertical equivalent muon for a standard md, and the q(vem)/q(e) shows a linear correlation with the water level. (c) 2017 elsevier b.v. all rights reserved.
WOS关键词ALTITUDE ; PROJECT
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics
WOS类目Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Nuclear ; Physics, Particles & Fields
语种英语
出版者ELSEVIER SCIENCE BV
WOS记录号WOS:000416483900001
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2178303
专题高能物理研究所
通讯作者Zuo, Xiong
作者单位1.Chinese Acad Sci, Key Lab Particle Astrophy, Inst High Energy Phys, Beijing 100049, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Southwest Jiaotong Univ, Chengdu 611756, Sichuan, Peoples R China
4.Hebei Normal Univ, Shijiazhuang 050024, Hebei, Peoples R China
5.Tsinghua Univ, Beijing 100084, Peoples R China
推荐引用方式
GB/T 7714
Zuo, Xiong,Xiao, Gang,Feng, Shaohui,et al. Calibration and monitoring of lhaaso-km2a muon detectors with muon decay events[J]. Nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment,2018,879:1-5.
APA Zuo, Xiong.,Xiao, Gang.,Feng, Shaohui.,Li, Xiurong.,Li, Cong.,...&Saeed, Mohsin.(2018).Calibration and monitoring of lhaaso-km2a muon detectors with muon decay events.Nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment,879,1-5.
MLA Zuo, Xiong,et al."Calibration and monitoring of lhaaso-km2a muon detectors with muon decay events".Nuclear instruments & methods in physics research section a-accelerators spectrometers detectors and associated equipment 879(2018):1-5.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace