CORC  > 高能物理研究所
Beam hardening correction for a cone-beam ct system and its effect on spatial resolution
Zhao Wei1,2,3; Fu Guo-Tao1,2,3; Sun Cui-Li1,2; Wang Yan-Fang1,2; Wei Cun-Feng1,2; Cao Da-Quan1,2,3; Que Jie-Min1,2; Tang Xiao1,2,3; Shi Rong-Jian1,2; Wei Long1,2
刊名Chinese physics c
2011-10-01
卷号35期号:10页码:978-985
关键词Beam hardening correction Cone-beam computed tomography Spatial resolution
ISSN号1674-1137
DOI10.1088/1674-1137/35/10/018
通讯作者Zhao wei(zhaow@ihep.ac.cn)
英文摘要In this paper, we present a beam hardening correction (bhc) method in three-dimension space for a cone-beam computed tomography (cbct) system in a mono-material case and investigate its effect on the spatial resolution. due to the polychromatic character of the x-ray spectrum used, cupping and streak artifacts called beam hardening artifacts arise in the reconstructed ct images, causing reduced image quality. in addition, enhanced edges are introduced in the reconstructed ct images because of the beam hardening effect. the spatial resolution of the cbct system is calculated from the edge response function (erf) on different planes in space. thus, in the ct images with beam hardening artifacts, enhanced erfs will be extracted to calculate the modulation transfer function (mtf), obtaining a better spatial resolution that deviates from the real value. reasonable spatial resolution can be obtained after reducing the artifacts. the 10% mtf value and the full width at half maximum (fwhm) of the point spread function with and without bhc are presented.
WOS关键词COMPUTED-TOMOGRAPHY
WOS研究方向Physics
WOS类目Physics, Nuclear ; Physics, Particles & Fields
语种英语
出版者CHINESE PHYSICAL SOC
WOS记录号WOS:000295742500018
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2176139
专题高能物理研究所
通讯作者Zhao Wei
作者单位1.CAS, Inst High Energy Phys, Key Lab Nucl Analyt Tech, Beijing 100049, Peoples R China
2.Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhao Wei,Fu Guo-Tao,Sun Cui-Li,et al. Beam hardening correction for a cone-beam ct system and its effect on spatial resolution[J]. Chinese physics c,2011,35(10):978-985.
APA Zhao Wei.,Fu Guo-Tao.,Sun Cui-Li.,Wang Yan-Fang.,Wei Cun-Feng.,...&Yu Zhong-Qiang.(2011).Beam hardening correction for a cone-beam ct system and its effect on spatial resolution.Chinese physics c,35(10),978-985.
MLA Zhao Wei,et al."Beam hardening correction for a cone-beam ct system and its effect on spatial resolution".Chinese physics c 35.10(2011):978-985.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace