Performance evaluation of a parallel-hole collimated detector module for animal spect imaging | |
Huang Xian-Chao1,2,3; Zhang Zhi-Ming1,2; Li Dao-Wu1,2; Tang Hao-Hui1,2; Li Ting1,2; Liao Yan-Fei1,2,3; Liu Jun-Hui1,2,3; Wang Pei-Lin1,2,3; Chen Yan1,2,3; Wang Ying-Jie1,2,3 | |
刊名 | Chinese physics c |
2011-12-01 | |
卷号 | 35期号:12页码:1162-1165 |
关键词 | Animal imaging Spect parallel-hole collimator |
ISSN号 | 1674-1137 |
DOI | 10.1088/1674-1137/35/12/016 |
通讯作者 | Huang xian-chao() |
英文摘要 | We have built and investigated a detector module for animal spect imaging, especially for use in large field of view (fov) conditions. the module consists of a pmt-based detector and a parallel-hole collimator with an effective area of 80 mm x 80 mm. the detector is composed of a nai scintillation crystal array coupled to four 118500 position sensitive photomultiplier tubes (ps-pmt). the intrinsic energy resolution of the detector is 11.5% at 140 kev on average. the planar spatial resolution of the module changes from 2.2 mm to 5.1 mm at different source-to-collimator distances with an unchanged sensitivity of about 34cps/mbq. additionally, the spect micro deluxe phantom imaging was performed with a radius of rotation (ror) of 40 mm. using the fbp reconstruction algorithm, a high performance image was obtained, indicating the feasibility of this detector module. |
WOS关键词 | SYSTEM ; CAMERA |
WOS研究方向 | Physics |
WOS类目 | Physics, Nuclear ; Physics, Particles & Fields |
语种 | 英语 |
出版者 | CHINESE PHYSICAL SOC |
WOS记录号 | WOS:000297908600016 |
内容类型 | 期刊论文 |
URI标识 | http://www.corc.org.cn/handle/1471x/2176043 |
专题 | 高能物理研究所 |
通讯作者 | Huang Xian-Chao |
作者单位 | 1.Chinese Acad Sci, Key Lab Nucl Analyt Tech, Inst High Energy Phys, Beijing 100049, Peoples R China 2.Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China 3.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Huang Xian-Chao,Zhang Zhi-Ming,Li Dao-Wu,et al. Performance evaluation of a parallel-hole collimated detector module for animal spect imaging[J]. Chinese physics c,2011,35(12):1162-1165. |
APA | Huang Xian-Chao.,Zhang Zhi-Ming.,Li Dao-Wu.,Tang Hao-Hui.,Li Ting.,...&Wang Bao-Yi.(2011).Performance evaluation of a parallel-hole collimated detector module for animal spect imaging.Chinese physics c,35(12),1162-1165. |
MLA | Huang Xian-Chao,et al."Performance evaluation of a parallel-hole collimated detector module for animal spect imaging".Chinese physics c 35.12(2011):1162-1165. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论