Fabrication of Dry Electrode for Recording Bio-potentials | |
Guo K | |
刊名 | chinese physics letters |
2011 | |
卷号 | 28期号:1页码:article no.10701 |
关键词 | AG/AGCL REFERENCE ELECTRODE SENSOR |
ISSN号 | 0256-307x |
通讯作者 | wang, y, lanzhou univ, inst microelect, sch phys sci & technol, lanzhou 730000, peoples r china. peiwh@semi.ac.cn |
学科主题 | 光电子学 |
收录类别 | SCI |
资助信息 | national natural science foundation of china [60776024, 60877035, 90820002]; national high-technology research and development program of china [2007aa03z427, 2007aa04z329, 2007aa04z254] |
语种 | 英语 |
公开日期 | 2011-07-05 ; 2011-07-15 |
附注 | development of minimally invasive dry electrodes for recording biopotentials is presented. the detailed fabrication process is outlined. a dry electrode is formed by a number of microneedles. the lengths of the microneedles are about 150 mu m and the diameters are about 50 mu m. the tips of the microneedles are sharp enough to penetrate into the skin. the silver/silver chloride is grown on microneedle arrays and demonstrates good character. the electrocardiogram shows that the dry electrode is suitable for recording biopotentials. |
内容类型 | 期刊论文 |
源URL | [http://ir.semi.ac.cn/handle/172111/21021] |
专题 | 半导体研究所_集成光电子学国家重点实验室 |
推荐引用方式 GB/T 7714 | Guo K. Fabrication of Dry Electrode for Recording Bio-potentials[J]. chinese physics letters,2011,28(1):article no.10701. |