Conductive Ag-Based Modification of Hydroxyapatite Microtubule Array and Its Application to Enzyme-Free Glucose Sensing | |
Jiang, Yingying3; Liu, Haiyan; Qi, Xuan; Sun, Jun; Li, Mei1,2; Wang, Jun | |
刊名 | CHEMISTRYSELECT |
2018 | |
卷号 | 3期号:9页码:2542 |
关键词 | conductive modification enzyme-free glucose sensing hydroxyapatite microtubule array polyaniline |
ISSN号 | 2365-6549 |
DOI | 10.1002/slct.201702803 |
英文摘要 | Plenty of biomineralized hydroxyapatite (BioHAP) matrix microtubules (named dentin tubules) with regular arrangement are inside mammal tooth dentin. Herein, electrically conductive polyaniline (PANI) is applied to modify the microtubule array to assemble a PANI/BioHAP composite through an in-situ polymerization method. On this basis, a sensor (PANI/BioHAP/AgHg) is assembled with PANI/BioHAP and silver amalgam, and further applied to enzyme-free glucose sensing. The inner-wall of the tubules is treated in advance with p-methylbenzene sulfonic acid to alter its hydrophilism into hydrophobicity. The treatment contributes to improve the diffusibility of aniline monomer in the tubules and to form a PANI conductive network on the wall. Meanwhile, a large quantity of active sites on the surface of BioHAP matrix performs both adsorption and concentration to glucose molecules. The special array structure helps to shield undesired electrochemical signals, and also increases the current response of glucose electro-catalytic oxidation. |
学科主题 | Chemistry, Multidisciplinary |
出版者 | WILEY-V C H VERLAG GMBH |
WOS记录号 | WOS:000426765100017 |
内容类型 | 期刊论文 |
源URL | [http://ir.sic.ac.cn/handle/331005/25104] |
专题 | 中国科学院上海硅酸盐研究所 |
作者单位 | 1.Northeastern Univ, Dept Chem, 11,Lane 3rd Wenhua Rd, Shenyang 110819, Liaoning, Peoples R China 2.Univ Bristol, Ctr Protolife Res, Bristol BS8 1TS, Avon, England 3.Univ Bristol, Ctr Organized Matter Chem, Sch Chem, Bristol BS8 1TS, Avon, England 4.Chinese Acad Sci, Shanghai Inst Ceram, State Key Lab High Performance Ceram & Superfine, Shanghai 200050, Peoples R China |
推荐引用方式 GB/T 7714 | Jiang, Yingying,Liu, Haiyan,Qi, Xuan,et al. Conductive Ag-Based Modification of Hydroxyapatite Microtubule Array and Its Application to Enzyme-Free Glucose Sensing[J]. CHEMISTRYSELECT,2018,3(9):2542, 2547. |
APA | Jiang, Yingying,Liu, Haiyan,Qi, Xuan,Sun, Jun,Li, Mei,&Wang, Jun.(2018).Conductive Ag-Based Modification of Hydroxyapatite Microtubule Array and Its Application to Enzyme-Free Glucose Sensing.CHEMISTRYSELECT,3(9),2542. |
MLA | Jiang, Yingying,et al."Conductive Ag-Based Modification of Hydroxyapatite Microtubule Array and Its Application to Enzyme-Free Glucose Sensing".CHEMISTRYSELECT 3.9(2018):2542. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论