Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan
Huang, Qinghua1,2; Wu, Bowen3; Lan, Jiulong3; Li, Xuelong4; Huang, QH (reprint author), Northwestern Polytech Univ, Sch Mech Engn, Xian 710072, Peoples R China.
刊名IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS
2018-04-01
卷号12期号:2页码:426-436
关键词Automatic Ultrasound Scanning Depth Imaging Robotic 3d Ultrasound Scan Path Planning
ISSN号1932-4545
DOI10.1109/TBCAS.2017.2782815
产权排序4
文献子类Article
英文摘要

Robotic ultrasound systems have turned into clinical use over the past few decades, increasing precision and quality of medical operations. In this paper, we propose a fully automatic scanning system for three-dimensional (3-D) ultrasound imaging. A depth camera was first used to obtain the depth data and color data of the tissue surface. Based on the depth image, the 3-D contour of the tissue was rendered and the scan path of ultrasound probe was automatically planned. Following the scan path, a 3-D translating device drove the probe to move on the tissue surface. Simultaneously, the B-scans and their positional information were recorded for subsequent volume reconstruction. In order to stop the scanning process when the pressure on the skin exceeded a preset threshold, two force sensors were attached to the front side of the probe for forcemeasurement. In vitro and in vivo experiments were conducted for assessing the performance of the proposed system. Quantitative results show that the error of volume measurement was less than 1%, indicating that the system is capable of automatic ultrasound scanning and 3-D imaging. It is expected that the proposed system can be well used in clinical practices.

学科主题Engineering, Biomedical
WOS关键词RECONSTRUCTION ALGORITHMS ; MUSCULOSKELETAL TISSUES ; FREEHAND ULTRASOUND ; MEDICAL ULTRASOUND ; SYSTEM ; PROSTATE ; BIOPSY ; ARRAYS ; IMAGES ; CALIBRATION
WOS研究方向Engineering
语种英语
WOS记录号WOS:000428547600015
资助机构National Natural Science Foundation of China(61372007 ; Guangzhou Key Lab of Body Data Science(201605030011) ; Natural Science Foundation of Guangdong Province, China(2017A030312006 ; Project of Science and Technology Department of Guangdong Province(2014A050503020 ; Science and Technology Program of Guangzhou(201704020134) ; 61571193) ; 2015A030313210) ; 2016A010101021 ; 2016A010101022 ; 2016A010101023)
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/30036]  
专题西安光学精密机械研究所_光学影像学习与分析中心
通讯作者Huang, QH (reprint author), Northwestern Polytech Univ, Sch Mech Engn, Xian 710072, Peoples R China.
作者单位1.Northwestern Polytech Univ, Sch Mech Engn, Xian 710072, Peoples R China
2.Northwestern Polytech Univ, Ctr Opt Imagery Anal & Learning, Xian 710072, Peoples R China
3.South China Univ Technol, Sch Elect & Informat Engn, Guangzhou 510006, Guangdong, Peoples R China
4.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Shaanxi, Peoples R China
推荐引用方式
GB/T 7714
Huang, Qinghua,Wu, Bowen,Lan, Jiulong,et al. Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan[J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS,2018,12(2):426-436.
APA Huang, Qinghua,Wu, Bowen,Lan, Jiulong,Li, Xuelong,&Huang, QH .(2018).Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan.IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS,12(2),426-436.
MLA Huang, Qinghua,et al."Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan".IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 12.2(2018):426-436.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace