System calibration method for Fourier ptychographic microscopy
Pan, An1,2; Zhang, Yan1,2; Zhao, Tianyu1,2; Wang, Zhaojun1,2; Dan, Dan1,2; Lei, Ming1; Yao, Baoli1
刊名JOURNAL OF BIOMEDICAL OPTICS
2017-09-01
卷号22期号:9
关键词Computational Imaging Phase Retrieval Fourier Ptychography
ISSN号1083-3668
DOI10.1117/1.JBO.22.9.096005
产权排序1
文献子类Article
英文摘要

Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)

WOS关键词LED ARRAY MICROSCOPE ; ILLUMINATION ; FIELD
WOS研究方向Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
语种英语
WOS记录号WOS:000413570000029
资助机构National Natural Science Foundation of China (NSFC)(61377008 ; 81427802)
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/29392]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian, Shaanxi, Peoples R China
2.Univ Chinese Acad Sci, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Pan, An,Zhang, Yan,Zhao, Tianyu,et al. System calibration method for Fourier ptychographic microscopy[J]. JOURNAL OF BIOMEDICAL OPTICS,2017,22(9).
APA Pan, An.,Zhang, Yan.,Zhao, Tianyu.,Wang, Zhaojun.,Dan, Dan.,...&Yao, Baoli.(2017).System calibration method for Fourier ptychographic microscopy.JOURNAL OF BIOMEDICAL OPTICS,22(9).
MLA Pan, An,et al."System calibration method for Fourier ptychographic microscopy".JOURNAL OF BIOMEDICAL OPTICS 22.9(2017).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace