Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform
Cui Hai-bin1; Yang Ke1,2; Zhang Long1; Wu Xiao-song1; Liu Yong1; Wang An1; Li Hui3; Ji Min1
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
2016-09-01
卷号36期号:9页码:2997-3002
关键词Tdlas Gabor Transform Second Harmonic Denoising
DOI10.3964/j.issn.1000-0593(2016)09-2997-06
文献子类Article
英文摘要Tunable diode laser absorption spectroscopy (TDLAS) technology combined with wavelength modulation spectroscopy (WMS) technology is an important technique for trace gas detection. Detected with the lock-in amplifier, the second harmonic signal obtained after demodulation is analyzed to get the gas absorption information. However, the second harmonic signal is affected by noise which reduces the accuracy and stability of the detection system. To improve the signal to noise ratio (SNR) of the TDLAS detection system, a denoising method based on Gabor transform is proposed for second harmonic signal noise reduction. Taking the CH4 absorption spectrum at 1 653. 72 nm as an example, the effectiveness of the noise reduction method is verified through simulation and experiments. The simulation results show that the signal to noise ratio for the second harmonic signal of 0 dB can be improved 15. 73 dB with Gabor transform-based denoising method. Experimental results show that with the Gabor transform-based denoising method, the linear correlation coefficient r can be as high as 0. 996 59 between the second harmonic peak value and the CH4 concentration in the range of 0. 001%similar to 0. 02%. At the same time, the detection accuracy and stability of the system have been improved significantly.
WOS关键词WAVELET TRANSFORM ; NOISE-REDUCTION ; ENHANCEMENT
WOS研究方向Spectroscopy
语种英语
WOS记录号WOS:000383306800049
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/24729]  
专题合肥物质科学研究院_应用技术研究所
作者单位1.Chinese Acad Sci, Hefei Inst Phys Sci, Inst Appl Technol, Hefei 230031, Peoples R China
2.Univ Sci & Technol China, Hefei 230026, Peoples R China
3.Beijing Tobacco Qual Supervis & Test Stn, Beijing 100029, Peoples R China
推荐引用方式
GB/T 7714
Cui Hai-bin,Yang Ke,Zhang Long,et al. Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2016,36(9):2997-3002.
APA Cui Hai-bin.,Yang Ke.,Zhang Long.,Wu Xiao-song.,Liu Yong.,...&Ji Min.(2016).Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform.SPECTROSCOPY AND SPECTRAL ANALYSIS,36(9),2997-3002.
MLA Cui Hai-bin,et al."Tunable Diode Laser Absorption Spectroscopy (TDLAS) Detection Signal Denoising Based on Gabor Transform".SPECTROSCOPY AND SPECTRAL ANALYSIS 36.9(2016):2997-3002.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace