Design of an Extended Range Long Counter Using Super Monte Carlo Simulation | |
Mazunga, Mohamed1,2; Li, Taosheng2; Li, Yanan2; Hong, Bing2; Wang, Yongfeng2; Ji, Xiang2 | |
刊名 | RADIATION PROTECTION DOSIMETRY |
2017-07-01 | |
卷号 | 175期号:3页码:413-417 |
DOI | 10.1093/rpd/ncw368 |
文献子类 | Article |
英文摘要 | We have designed an extended range neutron long counter on the basis of work optimized using SuperMC code. The problem of the existing traditional long counters is that their response function falls rapidly above 5 MeV. We proposed a new designed by adding two layers of converter material inside the polyethylene moderator. The relatively low density chromium and high density lead metals convert high energy neutron by (n, xn) spallation reaction. This produces more neutrons of lower energies, which have higher probability of being detected by thermal He-3-counter. The response function at lower neutron energies was improved by inserting small polyethylene cylinder in front of He-3 counter. In this design we achieved to extent the flat response function of the long counter from few keV up to 150 MeV. The total fluctuation of response curve is less than +/- 9% over the entire energy range. The designed long counter is suitable to be used as neutron monitor for monitoring neutron inotsign,uence at high-energy neutron source. |
WOS关键词 | CONCEPTUAL DESIGN ; ENERGY-RANGE ; NEUTRON ; CALIBRATION ; CHINA |
WOS研究方向 | Environmental Sciences & Ecology ; Public, Environmental & Occupational Health ; Nuclear Science & Technology ; Radiology, Nuclear Medicine & Medical Imaging |
语种 | 英语 |
WOS记录号 | WOS:000405898800016 |
资助机构 | National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) ; National Natural Science Foundation of China(11505219) |
内容类型 | 期刊论文 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/33535] |
专题 | 合肥物质科学研究院_中国科学院核能安全技术研究所 |
作者单位 | 1.Univ Sci & Technol China, Hefei 230027, Anhui, Peoples R China 2.Chinese Acad Sci, Key Lab Neutron & Radiat Safety, Inst Nucl Energy Safety Technol, Hefei 230031, Anhui, Peoples R China |
推荐引用方式 GB/T 7714 | Mazunga, Mohamed,Li, Taosheng,Li, Yanan,et al. Design of an Extended Range Long Counter Using Super Monte Carlo Simulation[J]. RADIATION PROTECTION DOSIMETRY,2017,175(3):413-417. |
APA | Mazunga, Mohamed,Li, Taosheng,Li, Yanan,Hong, Bing,Wang, Yongfeng,&Ji, Xiang.(2017).Design of an Extended Range Long Counter Using Super Monte Carlo Simulation.RADIATION PROTECTION DOSIMETRY,175(3),413-417. |
MLA | Mazunga, Mohamed,et al."Design of an Extended Range Long Counter Using Super Monte Carlo Simulation".RADIATION PROTECTION DOSIMETRY 175.3(2017):413-417. |