Design of coolant distribution system (CDS) for ITER PF AC/DC converter
Guo, Bin1; Song, Zhiquan1; Fu, Peng1; Xu, Xuesong1; Li, Chuan1; Wang, Min2; Dong, Lin2
刊名FUSION ENGINEERING AND DESIGN
2016-10-01
卷号108期号:页码:21-27
关键词Coolant Distribution System Design Thermal-hydraulic Ac/dc Converter
DOI10.1016/j.fusengdes.2016.04.027
文献子类Article
英文摘要The Poloidal Field (PF) converter unit, playing an essential role in the plasma shape and position control in vertical and horizontal direction, which is an important part of ITER power supply system. As an important subsystem of the converter unit, the coolant distribution system has the function to distribute the cooling water from ITER component cooling water system (CCWS) to its main components at the required flow rate, pressure and temperature. This paper presents the thermal hydraulic design of coolant distribution system for the ITER PF converter unit. Different operational requirements of the PF converter unit regarding flow rate, temperature and pressure have been analyzed to design the system process and arrangement. A thermal-hydraulic analysis model has been built to size the system and predict the flow rate and temperature distribution of the system under the normal operation. Based on the system thermal-hydraulic analysis results, the system pressure profile has been plotted to evaluate the pressure behavior along each client flow path. A CDS prototype for the ITER PF converter has been constructed and some experiments have been performed on it. A good agreement of the flow distribution and temperature behavior between the simulated and test results validate the proposed design methodology. (C) 2016 Elsevier B.V. All rights reserved.
WOS研究方向Nuclear Science & Technology
语种英语
WOS记录号WOS:000377736500003
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/21718]  
专题合肥物质科学研究院_中科院等离子体物理研究所
作者单位1.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
2.China Int Nucl Fus Energy Program Execut Ctr, Beijing 100862, Peoples R China
推荐引用方式
GB/T 7714
Guo, Bin,Song, Zhiquan,Fu, Peng,et al. Design of coolant distribution system (CDS) for ITER PF AC/DC converter[J]. FUSION ENGINEERING AND DESIGN,2016,108(无):21-27.
APA Guo, Bin.,Song, Zhiquan.,Fu, Peng.,Xu, Xuesong.,Li, Chuan.,...&Dong, Lin.(2016).Design of coolant distribution system (CDS) for ITER PF AC/DC converter.FUSION ENGINEERING AND DESIGN,108(无),21-27.
MLA Guo, Bin,et al."Design of coolant distribution system (CDS) for ITER PF AC/DC converter".FUSION ENGINEERING AND DESIGN 108.无(2016):21-27.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace