Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance
Zhu, Baoqiang; Liu, Chong; Ji, Lailin; Yang, Lin; Zhao, Dongfeng; Zhang, Yanfeng; Liu, Dong; Lin, Zunqi
刊名Appl. Optics
2016
卷号55期号:10页码:2800
通讯作者jsycjll@siom.ac.cn
英文摘要In order to obtain the intensity distribution of a 351 nm focal spot and smoothing by spectral dispersion (SSD) focal plane profile of a SGII-upgraded facility, a type of off-axis imaging system with three spherical mirrors, suitable for a finite distance source point to be imaged near the diffraction limit has been designed. The quality factor of the image system is 1.6 times of the diffraction limit tested by a 1053 nm point source. Because of the absence of a 351 nm point source, we can use a Collins diffraction imaging integral with respect to lambda = 351 nm, corresponding to a quality factor that is 3.8 times the diffraction limit at 351 nm. The calibration results show that at least the range of +/- 10 mrad of view field angle and +/- 50 mm along the axial direction around the optimum object distance can be satisfied with near diffraction limited image that is consistent with the design value. Using this image system, the No. 2 beam of the SGII-upgraded facility has been tested. The test result of the focal spot of final optics assembly (FOA) at 351 nm indicates that about 80% of energy is encompassed in 14.1 times the diffraction limit, while the output energy of the No. 2 beam is 908 J at 1053 nm. According to convolution theorem, the true value of a 351 nm focal spot of FOA is about 12 times the diffraction limit because of the influence of the quality factor. Further experimental studies indicate that the RMS value along the smoothing direction is less than 15.98% in the SSD spot test experiment. Computer simulations show that the quality factor of the image system used in the experiment has almost no effect on the SSD focal spot test. The image system can remarkably distort the SSD focal spot distribution under the circumstance of the quality factor 15 times worse than the diffraction limit. The distorted image shows a steep slope in the contour of the SSD focal spot along the smoothing direction that otherwise has a relatively flat top region around the focal spot center. (C) 2016 Optical Society of America
收录类别SCI
资助信息National Natural Science Foundation of China (NSFC) [U1330129]
WOS记录号WOS:000373400800043
内容类型期刊论文
源URL[http://ir.siom.ac.cn/handle/181231/28003]  
专题上海光学精密机械研究所_高功率激光物理国家实验室
作者单位中国科学院上海光学精密机械研究所
推荐引用方式
GB/T 7714
Zhu, Baoqiang,Liu, Chong,Ji, Lailin,et al. Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance[J]. Appl. Optics,2016,55(10):2800.
APA Zhu, Baoqiang.,Liu, Chong.,Ji, Lailin.,Yang, Lin.,Zhao, Dongfeng.,...&Lin, Zunqi.(2016).Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance.Appl. Optics,55(10),2800.
MLA Zhu, Baoqiang,et al."Studies on design of 351 nm focal plane diagnostic system prototype and focusing characteristic of SGII-upgraded facility at half achievable energy performance".Appl. Optics 55.10(2016):2800.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace