CORC  > 厦门大学  > 医学院-已发表论文
Influence of Refractive Error on Optic Disc Topographic Parameters: The Singapore Malay Eye Study
Wu, Ren-Yi ; Wong, Tien-Yin ; Zheng, Ying-Feng ; Cheung, Carol Yim-Lui ; Perera, Shamira A. ; Saw, Seang Mei ; Aung, Tin ; Wu RY(吴仁毅)
刊名http://dx.doi.org/10.1016/j.ajo.2011.01.018
2011-07
关键词NERVE-FIBER LAYER SCANNING LASER OPHTHALMOSCOPY HEIDELBERG RETINA TOMOGRAPHY COHERENCE TOMOGRAPHY DETECTING GLAUCOMA MYOPIC EYES POPULATION PREVALENCE THICKNESS HEAD
英文摘要NATIONAL Medical Research Council, Singapore [0796/2003, 0863/2004, CSI/0002/2005]; Biomedical Research Council, Singapore [501/1/25-5]; Singapore Tissue Network; Ministry of Health, Singapore, Republic of Singapore; PURPOSE: To examine the relationship between refractive error and optic disc topographic parameters and retinal nerve fiber layer (RNFL) thickness. DESIGN: Population-based cross-sectional study. METHODS: All 3280 (78.7% response rate) persons of Asian Malay ethnicity 40 to 80 years of age underwent a standardized interview, ocular examinations, and optic disc imaging with the Heidelberg Retina Tomography II (HRT; Heidelberg Engineering). Associations between spherical equivalent (SE) and HRT parameters were evaluated by partial correlation analysis. RESULTS: There were 2457 (74.9%) right eyes with good-quality HRT images for analyses. When compared with emmetropic 'eyes, highly myopic eyes (SE < -6.0 diopters) had greater disc area, rim area, rim volume, whereas hyperopic eyes (SE > 0.5 diopters) had significantly smaller disc area, rim area, and cross-sectional RNFL area (all P < .005). In partial correlation after adjustment for age, sex, body mass index, intraocular pressure, and optic disc area, increase of SE (toward hyperopia) was related significantly with greater cup area (partial correlation coefficient, r = 0.058; P = .004) and cup-to-disc area ratio (r = 0.058; P = .004) and with smaller optic disc area (r = 0.058; P = .004), rim area (r = 0.058; P = .004), and rim volume (r = 0.091; P < .001). CONCLUSIONS: This population-based study shows that refractive error is significantly (but weakly) associated with HRT parameters of disc area, cup area, rim area, cup-to-disc area ratio, and rim volume. The clinical significance of these associations need to be determined in further studies. (Am J Ophthalmol 2011;152:81-86. (C) 2011 by Elsevier Inc. All rights reserved.)
语种英语
出版者AM J OPHTHALMOL
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/93287]  
专题医学院-已发表论文
推荐引用方式
GB/T 7714
Wu, Ren-Yi,Wong, Tien-Yin,Zheng, Ying-Feng,et al. Influence of Refractive Error on Optic Disc Topographic Parameters: The Singapore Malay Eye Study[J]. http://dx.doi.org/10.1016/j.ajo.2011.01.018,2011.
APA Wu, Ren-Yi.,Wong, Tien-Yin.,Zheng, Ying-Feng.,Cheung, Carol Yim-Lui.,Perera, Shamira A..,...&吴仁毅.(2011).Influence of Refractive Error on Optic Disc Topographic Parameters: The Singapore Malay Eye Study.http://dx.doi.org/10.1016/j.ajo.2011.01.018.
MLA Wu, Ren-Yi,et al."Influence of Refractive Error on Optic Disc Topographic Parameters: The Singapore Malay Eye Study".http://dx.doi.org/10.1016/j.ajo.2011.01.018 (2011).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace