英文摘要利用一种罗丹明衍生物荧光探针的开环效应检测Hg2+.在PH 7.0的TrIS-HCl缓冲液中,Hg2+与荧光探针结合导致罗丹明类衍生物开环,溶液颜色由无色变成粉红色,并且发射强的荧光.荧光强度与Hg2+浓度在20~200 ng/l范围内呈良好的线性关系,检出限为4 ng/Ml.实验考察了荧光探针的选择性以及温度、PH、荧光试剂浓度和盐度对Hg2+检测的影响.结果表明该方法具有反应试剂水溶性好、选择性好和可常温检测等优点.方法应用于自来水、河水和湖水等水体中Hg2+的检测,获得较好的回收率.; The fluorescence enhancement of rhodamine derivative(RHD-1) was applied to the determination of Hg2+in water samples.Mercury ion interacted with the fluorescent probe in Tris-HCl buffer solution at pH 7.0,leading to the opening of RHD-1 structure,resulting in high fluorescence emission and the change of solution color.The fluorescence intensity was in proportion to the concentration of Hg2+ very well in the range of 20–200 ng/L,and the detection limit was found to be 4 ng/L.The effects of temperature,pH and the concentration of fluorescent reagent on the sensitivity and selectivity were investigated.The method was applied to detect Hg2+ in tap and lake water samples.The obtained result and sample recovery were all satisfactory.; 福建省质量技术监督局项目(FJQI2011014); 国家自然科学基金(20975085)资助
语种zh_CN
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/106825]  
专题化学化工-已发表论文
推荐引用方式
GB/T 7714
罗峰,陈冬梅,施雅梅,等. 基于罗丹明类衍生物荧光增强的水体中Hg~(2+)检测, Determination of Hg~(2+) in water using the fluorescence enhancement of rhodamine derivative[J],2013.
APA 罗峰,陈冬梅,施雅梅,&陈曦.(2013).基于罗丹明类衍生物荧光增强的水体中Hg~(2+)检测..
MLA 罗峰,et al."基于罗丹明类衍生物荧光增强的水体中Hg~(2+)检测".(2013).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace