微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅 | |
黄志勇 ; 陈发荣 ; 庄峙厦 ; 王小如 ; Frank S.C.Leeb | |
刊名 | http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003
![]() |
2012-06-05 ; 2012-06-05 | |
关键词 | 电感耦合等离子体质谱 流动注射 同位素稀释 海水 铅 ICPMS Flow injection Isotope dilution Seawater Lead O657.63 |
其他题名 | Determination of Trace Lead in Seawater by Isotope Dilution Method Coupled Micro-column Flow Injection and Inductively Coupled Plasma Mass Spectrometry (FI-ICP-MS) |
中文摘要 | 本文建立了用微柱流动注射与电感耦合等离子体质谱联用的同位素稀释分析方法。在优化条件下铅的检出限(3σ,n=6)为0.22ng/mL,对标准水样和加标海水的测定结果表明,方法的回收率分别为104.0%和94.8%。该法具有同位素稀释测量准确度高、操作简便的优点,能实现在线分离、富集和测定,及减少样品处理引入污染等特点,可应用于生物、环境等高盐样品中铅的在线分离测定。; An isotope dilution method, in which the chelating reaction of lead with 8hydroquinoline5sulfonic acid (8HQS) was used, for measuring trace lead in seawater by microcolumn flow injection and inductively coupled plasma mass spectrometry (IDFIICPMS) was established. The parameters of the hyphenated technique, such as the concentration of 8HQS, sample loading time and speed, washing time, eluent acid concentration and instrumental parameters of FIAICPMS were optimized and selected. The detection limits of this method estimated with threefold standard deviation of the procedure blank was 0.22 ng/mL. The recovery test of spiked Pb standard in seawater was 94.8%. In order to assess the accuracy of this method, standard reference water (GBW 08607) was used. The result is in good agreement with the certified value and the recovery was 104.0%. This method is recommended to determine the trace lead concentration in high salt matrix of samples.; 【作者单位】厦门大学现代分析科学教育部重点实验室; 香港浸会大学化学系 福建厦门 361005集美大学生物工程学院福建厦门 361021; 福建厦门 361005; 香港;【作者英文名】HUANG Zhiyong1,3, CHEN Farong1, ZHUANG Zhixia1,WANG Xiaoru1*, Frank S.C.Leeb2of China,Xiamen University, Xiamen Fujian361005;2. Department of Chemistry, Hong Kong Baptist University, Hong Kong;3. College of bioengine |
语种 | 中文 |
内容类型 | 期刊论文 |
源URL | [http://ir.calis.edu.cn/hdl/235041/18766] ![]() |
专题 | 集美大学 |
推荐引用方式 GB/T 7714 | 黄志勇,陈发荣,庄峙厦,等. 微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅[J]. http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003,2012, 2012. |
APA | 黄志勇,陈发荣,庄峙厦,王小如,&Frank S.C.Leeb.(2012).微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅.http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003. |
MLA | 黄志勇,et al."微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅".http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003 (2012). |