CORC  > 集美大学
微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅
黄志勇 ; 陈发荣 ; 庄峙厦 ; 王小如 ; Frank S.C.Leeb
刊名http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003
2012-06-05 ; 2012-06-05
关键词电感耦合等离子体质谱 流动注射 同位素稀释 海水 ICPMS Flow injection Isotope dilution Seawater Lead O657.63
其他题名Determination of Trace Lead in Seawater by Isotope Dilution Method Coupled Micro-column Flow Injection and Inductively Coupled Plasma Mass Spectrometry (FI-ICP-MS)
中文摘要本文建立了用微柱流动注射与电感耦合等离子体质谱联用的同位素稀释分析方法。在优化条件下铅的检出限(3σ,n=6)为0.22ng/mL,对标准水样和加标海水的测定结果表明,方法的回收率分别为104.0%和94.8%。该法具有同位素稀释测量准确度高、操作简便的优点,能实现在线分离、富集和测定,及减少样品处理引入污染等特点,可应用于生物、环境等高盐样品中铅的在线分离测定。; An isotope dilution method, in which the chelating reaction of lead with 8hydroquinoline5sulfonic acid (8HQS) was used, for measuring trace lead in seawater by microcolumn flow injection and inductively coupled plasma mass spectrometry (IDFIICPMS) was established. The parameters of the hyphenated technique, such as the concentration of 8HQS, sample loading time and speed, washing time, eluent acid concentration and instrumental parameters of FIAICPMS were optimized and selected. The detection limits of this method estimated with threefold standard deviation of the procedure blank was 0.22 ng/mL. The recovery test of spiked Pb standard in seawater was 94.8%. In order to assess the accuracy of this method, standard reference water (GBW 08607) was used. The result is in good agreement with the certified value and the recovery was 104.0%. This method is recommended to determine the trace lead concentration in high salt matrix of samples.; 【作者单位】厦门大学现代分析科学教育部重点实验室; 香港浸会大学化学系 福建厦门 361005集美大学生物工程学院福建厦门 361021; 福建厦门 361005; 香港;【作者英文名】HUANG Zhiyong1,3, CHEN Farong1, ZHUANG Zhixia1,WANG Xiaoru1*, Frank S.C.Leeb2of China,Xiamen University, Xiamen Fujian361005;2. Department of Chemistry, Hong Kong Baptist University, Hong Kong;3. College of bioengine
语种中文
内容类型期刊论文
源URL[http://ir.calis.edu.cn/hdl/235041/18766]  
专题集美大学
推荐引用方式
GB/T 7714
黄志勇,陈发荣,庄峙厦,等. 微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅[J]. http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003,2012, 2012.
APA 黄志勇,陈发荣,庄峙厦,王小如,&Frank S.C.Leeb.(2012).微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅.http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003.
MLA 黄志勇,et al."微柱流动注射同位素稀释电感耦合等离子体质谱法测定海水中的痕量铅".http://epub.edu.cnki.net/grid2008/brief/detailj.aspx?filename=fxkx200304001&dbcode=CJFQ&dbname=CJFQ2003 (2012).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace