抽水蓄能电站雷电侵入波保护的数值仿真 | |
陈水明 ; 康鹏 ; 何金良 ; 杨建军 ; 路剑 | |
2010-06-10 ; 2010-06-10 | |
关键词 | 雷电 侵入波 避雷器 冲击接地电阻 Lightning Intruding wave Surge arrestor Impulse grounding resistance TM862 |
其他题名 | Numerical Simulation of Lightning Protection against Intruding Wave in Pumped-storage Power Station |
中文摘要 | 采用PSCAD/EMTDC程序计算分析了江苏抽水蓄能电站500kV变电站雷电侵入波保护的效果,考虑了不同运行方式、不同雷击点的情况,还计算分析了杆塔冲击接地电阻、避雷器的布置及参数对保护效果的影响。计算结果表明,该工程的雷电侵入波保护避雷器的配置和接线方式可以满足安全可靠性的要求。; The scheme of lightning protection against intruding wave in Jiangsu pumped-storage power station is analyzed by numerical simulation with PSCAD/EMTDC in this paper. Some factors, including different operation mode and lightning strike location, are considered, and the effect of impulse grounding resistance of tower and layout of lightning arrestors on protection purpose is also analyzed. The calculated results indicate the scheme of lightning protection in this project is reasonable. |
语种 | 中文 ; 中文 |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/62135] ![]() |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | 陈水明,康鹏,何金良,等. 抽水蓄能电站雷电侵入波保护的数值仿真[J],2010, 2010. |
APA | 陈水明,康鹏,何金良,杨建军,&路剑.(2010).抽水蓄能电站雷电侵入波保护的数值仿真.. |
MLA | 陈水明,et al."抽水蓄能电站雷电侵入波保护的数值仿真".(2010). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论