Development of high-performance liquid chromatography and non-aqueous capillary electrophoresis methods for the determination of fenoxycarb residues in wheat samples | |
Liu, Mian ; Yang, Hui ; Liu, Hongxia ; Han, Po ; Wang, Xie ; Zhang, Shusheng ; Wu, Yangjie | |
2010-05-11 ; 2010-05-11 | |
关键词 | high performance liquid chromatography non-aqueous capillary electrophoresis fenoxycarb wheat residue SOLID-PHASE MICROEXTRACTION BOMBYX-MORI PESTICIDES SILKWORM DAPHNIA SPECTROMETRY DERIVATIVES EXTRACTION VEGETABLES SEPARATION Agriculture, Multidisciplinary Chemistry, Applied Food Science & Technology |
中文摘要 | BACKGROUND: Practical methods for the analysis of fenoxycarb residues in wheat samples were developed using high-performance liquid chromatography (HPLC) and non-aqueous capillary electrophoresis (NACE). RESULTS: Fenoxycarb residues in wheat were extracted with acetone by ultrasonication, followed by a clean-up procedure with liquid-liquid extraction with 5% NaCl/dichloromethane. The HPLC was developed using C18 as column, MeOH/water (6:4, v/v) as the mobile phase and 199 nm as the detection wavelength. The optimal NACE condition was established with the running buffer of 20.0 mmol L-1 NH4Ac in 95% MeOH (pH* 9.0), and the applied voltage of 30 kV over a capillary of 50 gm i.d. x 48.5 cm x 40 cm effective length. Both methods gave the relatively lower limits of detection (0.008 mg kg(-1) for HPLC and 0.024 mg kg(-1) for NACE) and the higher recoveries (>85.0%). They were successfully applied to the determination of fenoxycarb in wheat samples. CONCLUSION: The results showed that the fenoxycarb residue gradually reduced to trace amounts after about 3 years, which implied that the pharmacological actions of fenoxycarb could last for about 3 years. Meanwhile, more effort should be made to control and reduce fenoxycarb residues because of its potential health risks to consumers. (C) 2007 Society of Chemical Industry. |
语种 | 英语 ; 英语 |
出版者 | JOHN WILEY & SONS LTD ; CHICHESTER ; THE ATRIUM, SOUTHERN GATE, CHICHESTER PO19 8SQ, W SUSSEX, ENGLAND |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/26422] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Liu, Mian,Yang, Hui,Liu, Hongxia,et al. Development of high-performance liquid chromatography and non-aqueous capillary electrophoresis methods for the determination of fenoxycarb residues in wheat samples[J],2010, 2010. |
APA | Liu, Mian.,Yang, Hui.,Liu, Hongxia.,Han, Po.,Wang, Xie.,...&Wu, Yangjie.(2010).Development of high-performance liquid chromatography and non-aqueous capillary electrophoresis methods for the determination of fenoxycarb residues in wheat samples.. |
MLA | Liu, Mian,et al."Development of high-performance liquid chromatography and non-aqueous capillary electrophoresis methods for the determination of fenoxycarb residues in wheat samples".(2010). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论