Radiometric calibration of photographic camera with a composite plane array CCD in laboratory
Li, Jing; Zhao, Jian-Ke; Chang, Ming; Hu, Xin-Rong
刊名guangxue jingmi gongcheng/optics and precision engineering
2017
卷号25期号:1页码:73-83
ISSN号1004924x
其他题名复合面阵ccd摄影相机的实验室辐射定标
通讯作者li, jing (lijing@opt.ac.cn)
产权排序1
英文摘要

to eliminate the serious vignetting phenomenon and to solve the difficulty of choosing a relatively positioning target value problems among ccds during the radiometric calibration of the whole image plane of the photographic camera with a composite plane array ccd, a method for radiometric calibration of multi-ccds was proposed. after the dark signal calibration on each pixel, the gray value of the pixel in the vignetting area was revised, and by choosing the appropriate relative calibration target gray value of the whole image plane, the radiometric calibration of the photographic camera with a composite plane array ccd was eventually completed. through analysis of the gray distribution characteristics of vignetting area, the gray correction method for all kinds of explosion time and radiance was proposed. with calculation of fitting coefficient between each ccd gray value and the input radiance respectively, the coefficient with global minimum fitting error was chosen to calculate the relative calibration target gray value corresponding to radiance. after the radiometric calibration using this method, the non-uniformity of the whole image plane of the photographic camera with a composite plane array ccd is reduced from above 20% to better than 2%, and the accuracy of the absolute calibration is 4.23%. the result indicates that the proposed calibration method is appropriate for the calibration of composite planes array ccd. the accuracy of the calibration satisfies the radiometric calibration requirement of aerial cameras. © 2017, science press. all right reserved.

收录类别EI ; CSCD
语种中文
内容类型期刊论文
源URL[http://ir.opt.ac.cn/handle/181661/28928]  
专题西安光学精密机械研究所_检测技术研究中心
作者单位Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China
推荐引用方式
GB/T 7714
Li, Jing,Zhao, Jian-Ke,Chang, Ming,et al. Radiometric calibration of photographic camera with a composite plane array CCD in laboratory[J]. guangxue jingmi gongcheng/optics and precision engineering,2017,25(1):73-83.
APA Li, Jing,Zhao, Jian-Ke,Chang, Ming,&Hu, Xin-Rong.(2017).Radiometric calibration of photographic camera with a composite plane array CCD in laboratory.guangxue jingmi gongcheng/optics and precision engineering,25(1),73-83.
MLA Li, Jing,et al."Radiometric calibration of photographic camera with a composite plane array CCD in laboratory".guangxue jingmi gongcheng/optics and precision engineering 25.1(2017):73-83.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace