The test and analysis on pulse signal detection abilities of the X-ray detector MCP for pulsar navigation
Zhou, Qingyong1,2,3; Sheng, Lizhi4; Wei, Ziqing2,3; Liu, Siwei2,3; Jiang, Kun5; Chen, Chun4; Ji, Jianfeng2,3; Ren, Hongfei2,3; Ma, Gaofeng1
2017
会议名称8th china satellite navigation conference, csnc 2017
会议日期2017-05-23
会议地点shanghai, china
卷号438
页码637-647
通讯作者zhou, qingyong (zjlzqy1986@163.com)
英文摘要

the micro-channel plate detector (mcp) is an x-ray detecting system with a mature technology, which is suitable for space observation and navigation application of x-ray pulsar. for analyzing the x-ray pulse signal observation capability of mcp detector, a long-time experiment of mcp detector with different radiation flux and different background noise were carried out by the ground testing system. meanwhile, a set of evaluation methods of the pulse observation capability of x-ray detector was established, those expressions of the signal-to-noise ratio (snr), the correlation of pulse profile (r), the accuracy of pulse time of arrival (σtoa), the minimum detectable power (pmin) are derived from the photon counting model of the ground testing system. in the whole testing experiment which took almost a week, 8 groups of 10000 s x-ray photon toas dataset were received by the 20 cm2mcp detectors, the best periods were searched and gained, the observable pulse profiles were replicated, those characteristic parameters of pulse profile were estimated. the result of this experiment shows that the mcp detector has a good capability of x-ray pulse signal observation and reconstruction, the snr, r, σtoaof the observed pulse profile at the low pulse signal flux (fp= 0:05 ph/cm2/s) are (35.73, 88.38%, 51.53 µs) and are (35.73, 88.38%, 51.53 µs) at strong background noise (b = 16), so, the mcp detector has a good observation ability of a certain faint x ray pulsar. the result also has revealed that the minimum detectable power (pmin) of mcp detector is closely related to the power intensity of the x-ray pulsar simulator, is less correlation with the intensity of background noise. the pminhas the minimal value which is also called the minimum detectable cutoff power. when the x-ray pulse signal received by mcp detector is weak, pminis close to its minimal value (1 × 10-14w). © springer nature singapore pte ltd. 2017.

收录类别EI
产权排序4
会议录china satellite navigation conference, csnc 2017 proceedings
会议录出版者springer verlag
语种英语
ISSN号18761100
ISBN号9789811045905
内容类型会议论文
源URL[http://ir.opt.ac.cn/handle/181661/28904]  
专题西安光学精密机械研究所_光电子学研究室
作者单位1.Geographic Spatial Information Institute, Information Engineering University, Zhengzhou; 450052, China
2.Xi’an Research Institute of Surveying and Mapping, Xi’an; 710054, China
3.State Key Laboratory of Geo-information Engineering, Xi’an; 710054, China
4.Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710119, China
5.Beijing Tracking and Communication Technology Research Institute, Beijing; 100094, China
推荐引用方式
GB/T 7714
Zhou, Qingyong,Sheng, Lizhi,Wei, Ziqing,et al. The test and analysis on pulse signal detection abilities of the X-ray detector MCP for pulsar navigation[C]. 见:8th china satellite navigation conference, csnc 2017. shanghai, china. 2017-05-23.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace