A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses
Longo, M; Rigon, L; Lopez, FCM; Chen, RC; Dreossi, D; Zanconati, F; Longo, R
刊名PHYSICS IN MEDICINE AND BIOLOGY
2015
卷号60期号:3页码:N21—N34
关键词IMAGING TECHNIQUE RAY TOMOGRAPHY
英文摘要This work presents the first study of x-ray phase contrast imaging based on a simple implementation of the edge illumination method (EIXPCi) in the field of mammography with synchrotron radiation. A simplified EIXPCi set-up was utilized to study a possible application in mammography at clinical doses. Moreover, through a novel algorithm capable of separating and quantifying absorption and phase perturbations of images acquired in EIXPCi modality, it is possible to extract quantitative information on breast images, allowing an accurate tissue identification. The study was carried out at the SYRMEP beamline of Elettra synchrotron radiation facility (Trieste, Italy), where a mastectomy specimen was investigated with the EIXPCi technique. The sample was exposed at three different energies suitable for mammography with synchrotron radiation in order to test the validity of the novel algorithm in extracting values of linear attenuation coefficients integrated over the sample thickness. It is demonstrated that the quantitative data are in good agreement with the theoretical values of linear attenuation coefficients calculated on the hypothesis of the breast with a given composition. The results are promising and encourage the current efforts to apply the method in mammography with synchrotron radiation.
收录类别SCI
语种英语
公开日期2015-12-24
内容类型期刊论文
源URL[http://ir.sinap.ac.cn/handle/331007/24386]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
推荐引用方式
GB/T 7714
Longo, M,Rigon, L,Lopez, FCM,et al. A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses[J]. PHYSICS IN MEDICINE AND BIOLOGY,2015,60(3):N21—N34.
APA Longo, M.,Rigon, L.,Lopez, FCM.,Chen, RC.,Dreossi, D.,...&Longo, R.(2015).A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses.PHYSICS IN MEDICINE AND BIOLOGY,60(3),N21—N34.
MLA Longo, M,et al."A simplified edge illumination set-up for quantitative phase contrast mammography with synchrotron radiation at clinical doses".PHYSICS IN MEDICINE AND BIOLOGY 60.3(2015):N21—N34.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace